2018
DOI: 10.1002/mp.12745
|View full text |Cite
|
Sign up to set email alerts
|

Water equivalent PRESAGE® for synchrotron radiation therapy dosimetry

Abstract: The radiological response of a water equivalent PRESAGE dosimeter has been validated for synchrotron x-ray beam energies along with the ability to independently verify dose distributions of a MC model.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(10 citation statements)
references
References 23 publications
0
10
0
Order By: Relevance
“…The addition of DBTDL to this formulation also alters the Z eff of the PRESAGE dosimeter to be radiologically equivalent to water over a wide range of X-ray energies (Alqathami et al, 2015). Calculation of Z eff for this formulation of PRESAGE matches the Z eff of water within 1.7% over the effective energy range of 10 keV to 10 MeV (Gagliardi et al, 2018a).…”
Section: Nanoparticle Presage Dosimeter Fabricationmentioning
confidence: 99%
See 1 more Smart Citation
“…The addition of DBTDL to this formulation also alters the Z eff of the PRESAGE dosimeter to be radiologically equivalent to water over a wide range of X-ray energies (Alqathami et al, 2015). Calculation of Z eff for this formulation of PRESAGE matches the Z eff of water within 1.7% over the effective energy range of 10 keV to 10 MeV (Gagliardi et al, 2018a).…”
Section: Nanoparticle Presage Dosimeter Fabricationmentioning
confidence: 99%
“…Our previous investigations have demonstrated the radiological response of a water-equivalent (WE) PRESAGE over a range of X-ray energies (Gagliardi et al, 2018a) as well as the dose response and stability to synchrotron-generated X-rays (Gagliardi et al, 2018b).…”
Section: Introductionmentioning
confidence: 99%
“…For a pair production cross-section, PRESAGE has a maximum difference of 9% when compared with the water [ 84 ]. A study shows that PRESAGE has a percentage difference within 2% in photon absorption as compared with water over an energy range of 10 keV to 10 MeV, due to the addition of DBTDL, which was able to modify the effective atomic number of PRESAGE [ 90 ].…”
Section: Radiological Properties Of Presagementioning
confidence: 99%
“…Through 61,62 It is reported in the literature by Gagliardi et al that water-equivalent PRESAGE® is well suited for high-resolution 3D imaging of synchrotron-generated micro beams in stereotactic synchrotron radiotherapy (SSRT). 63 Gagliardi et al have investigated in their other exploration about the validation of the radiological response of water equivalent PRESAGE in 3D dosimetry for synchrotron X-ray photon energies. PRESAGE® was shaped into cylindrical rods with 70 mm in length and 43 mm in width.…”
Section: Presage® Dosimetry In Stereotactic Synchrotron Radiotherapymentioning
confidence: 99%
“…PRESAGE® showed an inability to measure field penumbra, but PRESAGE® possesses the potential to determine dose profiles which were calculated by MC model and verified by EBT3 films in SSRT and microbeam radiotherapy (MRT). 63…”
Section: Presage® Dosimetry In Stereotactic Synchrotron Radiotherapymentioning
confidence: 99%