Water Nitrate Remote Monitoring System with Self-Diagnostic Function for Ion-Selective Electrodes

Abstract: The detection of nitrate pollutants is a widely used strategy for protecting water sources. Although ion-selective electrodes (ISEs) have been considered for the determination of ion concentrations in water, the accuracy of ISE technology decreases owing to the signal drift and decreasing sensitivity over time. The objectives of the present study were: (1) to develop an online water monitoring system mainly consisting of an Arduino board-based Internet-of-Things (IoT) device and nitrate ISEs; and (2) to propos… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 31 publications
1
1
0
Order By: Relevance
“…Even when the concentration of the interfering ions decreased to 10 −4 M, these last two anions showed substantial interference (Figure S4 and Table 2). Nevertheless, the selectivity coefficients were similar to the ones reported for a similar ISM composition, either in electrodes with an inner liquid configuration [52,53] or with different solid-contact transducers [37,54]. This indicates that the selectivity of the studied sensors is a function of the ISM composition rather than the nature of the inner transducing element.…”
Section: Potentiometric Response Of Go-based All-solid-state No 3 -Isessupporting
confidence: 83%
“…Even when the concentration of the interfering ions decreased to 10 −4 M, these last two anions showed substantial interference (Figure S4 and Table 2). Nevertheless, the selectivity coefficients were similar to the ones reported for a similar ISM composition, either in electrodes with an inner liquid configuration [52,53] or with different solid-contact transducers [37,54]. This indicates that the selectivity of the studied sensors is a function of the ISM composition rather than the nature of the inner transducing element.…”
Section: Potentiometric Response Of Go-based All-solid-state No 3 -Isessupporting
confidence: 83%
“…Another approach for direct concentration measurements for anions has been developed based on a pulstrode protocol. 27 Submersible potentiometric probes 28,29 are by nature designed to perform measurements directly in the eld and have been used previously in environmental studies, 17,18,[30][31][32] but they require a pump to drive the sample towards the measuring site. To enable constant monitoring, the pump must run continually, which would lead to unreasonable power consumption and difficulties in deployment because of power source availability.…”
Section: Introductionmentioning