Wind loads on residential and large-scale solar collector models

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
14
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 35 publications
(15 citation statements)
references
References 12 publications
1
14
0
Order By: Relevance
“…A symmetric pressure distribution, with reference to the centerline of the inclined solar collector, is observed. Chung et al [5] found that the separation region on the upper surface of an inclined solar collector appears near the front edge and that there are vortices near the side edges, which results in a relatively larger negative mean surface pressure coefficient. After the pressure coefficient decreases gradually toward downstream from the leading edge, a minimum of 1.0 at / = 0.15 is observed.…”
Section: Mean Pressure Distributionsmentioning
confidence: 99%
See 1 more Smart Citation
“…A symmetric pressure distribution, with reference to the centerline of the inclined solar collector, is observed. Chung et al [5] found that the separation region on the upper surface of an inclined solar collector appears near the front edge and that there are vortices near the side edges, which results in a relatively larger negative mean surface pressure coefficient. After the pressure coefficient decreases gradually toward downstream from the leading edge, a minimum of 1.0 at / = 0.15 is observed.…”
Section: Mean Pressure Distributionsmentioning
confidence: 99%
“…Reynolds number independence was also noted. For a large-scale SWH (inclined solar collector or flat plate only), Chung et al [5,6] indicated that there is a higher suction force on the lower surface over the first half of the inclined solar collector and a stronger positive mean longitudinal differential pressure coefficient is observed. Kopp et al [7] further pointed that the presence of the building changed the aerodynamic loads substantially compared to ground-mounted systems.…”
Section: Introductionmentioning
confidence: 99%
“…The flat-plate solar collectors with glass covers are widely used in Taiwan. Chung et al [29,30] reported that the localized loads of a glazed flat-plate solar collector were higher near the front edge. The wind uplift of a solar collector considerably increased with the tilt angle (β) of the collector for both residential (a tilt solar collector with a horizontal cylinder as water storage tank) and large-scale (tilt solar collectors only) SWHs (Figure 8).…”
Section: Wind Loadsmentioning
confidence: 99%
“…Solar water heaters or photovoltaic systems, which are typically installed on the roofs of low-rise buildings, have been employed worldwide . Wind loads on inclined flat plates (or solar panels) have been reported (Wood et al, 2011;Kopp et al, 2002;Chung et al, 2008Chung et al, , 2011Chung et al, , 2013aChung et al, , 2013b. In particular, shifting reattachment points were observed on the upper surface at different tilt angles, imposing a considerable challenge on any correction scheme.…”
Section: Introductionmentioning
confidence: 99%