2013 North American Power Symposium (NAPS) 2013
DOI: 10.1109/naps.2013.6666880
|View full text |Cite
|
Sign up to set email alerts
|

Wind power impact on power system frequency response

Abstract: -The use of high power electronics in the large scale integration of wind power in the transmission and distribution systems can affect the system inertia response and the ability to recover frequency stability after large disturbances. Different approaches have been presented to show the system dynamic behaviour, and to quantify the wind power impact on the system inertial and frequency response. This paper gives a short overview of studies performed regarding the system inertia issues under high penetrations… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(19 citation statements)
references
References 38 publications
0
19
0
Order By: Relevance
“…These large synchronous machines react naturally to the frequency deviations and large inertia guarantees that the ROCOF will be slow enough so that power generation plants are able to react to the change in frequency, either by increasing or decreasing their powers depending whether change in frequency is negative or positive, respectively. In fully renewable energy based power systems the inertia will become low, since the rotating mass of the connected synchronous machine is reduced [44,45]. The lower inertia means that connected frequency regulation reserves must be able to respond faster than currently.…”
Section: Frequency Stabilitymentioning
confidence: 99%
See 1 more Smart Citation
“…These large synchronous machines react naturally to the frequency deviations and large inertia guarantees that the ROCOF will be slow enough so that power generation plants are able to react to the change in frequency, either by increasing or decreasing their powers depending whether change in frequency is negative or positive, respectively. In fully renewable energy based power systems the inertia will become low, since the rotating mass of the connected synchronous machine is reduced [44,45]. The lower inertia means that connected frequency regulation reserves must be able to respond faster than currently.…”
Section: Frequency Stabilitymentioning
confidence: 99%
“…The system inertia is low with high penetration of variable RE since the rotating mass of the connected synchronous machines is reduced. The lower inertia means that connected frequency regulation reserves must be able to respond faster than currently [44,45]. In this study, rate of change of frequency (ROCOF) when only synchronous generation (hydropower, biomass power plants, and geothermal units) contributes to the frequency balancing was first calculated.…”
Section: Introductionmentioning
confidence: 99%
“…Several approaches can be found in the literature on the contributions of frequency support to the regulation of wind turbines [25,26]. In general, VSWT provide negligible inertia since the fast control of power electronic converters maintains a practically constant output power irrespective of changes in the frequency of the grid [27].…”
Section: Introductionmentioning
confidence: 99%
“…Some of the aspects which can be affected by the inclusion of non-synchronous generation are the frequency control and inertia, the local system protection schemes, and the oscillatory stability [5], [6].…”
Section: Introductionmentioning
confidence: 99%