2001
DOI: 10.1016/s0969-806x(01)00301-2
|View full text |Cite
|
Sign up to set email alerts
|

X-ray Peltier cooled detectors for X-ray fluorescence analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0
1

Year Published

2004
2004
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 20 publications
(10 citation statements)
references
References 2 publications
0
9
0
1
Order By: Relevance
“…9 CdTe and its related compounds (e.g., CdZnTe, CdMnTe) can be used for radiation detection at different temperatures. At À60 C, energy resolutions (FWHM) of 310 eV and 600 eV at 5.9 keV and 59 keV, respectively, were reported using CdTe detector; 10 at À37 C, FWHM of 311 eV and 824 eV at 5.9 keV and 59 keV, respectively, were demonstrated for a CdZnTe detector. 11 These compounds can also operate at increased temperatures, albeit with degraded energy resolution: for example, 53 keV (FWHM) at 122 keV was observed for CdTe at 92 C, 12 whilst a 9.4 keV (FWHM) at 32 keV was reported for CdZnTe at 70 C. 13 CdTe and CdZnTe are attractive choices for producing large area radiation detectors, and for this reason, they have received considerable research attention; 14 spectroscopic CdZnTe and CdTe detector imaging arrays, for example, have been proven by Wilson et al…”
Section: Introductionmentioning
confidence: 99%
“…9 CdTe and its related compounds (e.g., CdZnTe, CdMnTe) can be used for radiation detection at different temperatures. At À60 C, energy resolutions (FWHM) of 310 eV and 600 eV at 5.9 keV and 59 keV, respectively, were reported using CdTe detector; 10 at À37 C, FWHM of 311 eV and 824 eV at 5.9 keV and 59 keV, respectively, were demonstrated for a CdZnTe detector. 11 These compounds can also operate at increased temperatures, albeit with degraded energy resolution: for example, 53 keV (FWHM) at 122 keV was observed for CdTe at 92 C, 12 whilst a 9.4 keV (FWHM) at 32 keV was reported for CdZnTe at 70 C. 13 CdTe and CdZnTe are attractive choices for producing large area radiation detectors, and for this reason, they have received considerable research attention; 14 spectroscopic CdZnTe and CdTe detector imaging arrays, for example, have been proven by Wilson et al…”
Section: Introductionmentioning
confidence: 99%
“…Table 3 shows the energy resolution for Si (p-i-n), CdTe (p-i-n) and CdZnTe detectors developed at Baltic Scientific Instruments. 4,7 Si p-i-n detectors have an energy resolution already close to that of Si(Li) detectors. However, they compare unfavorably with the latter in terms of registered energies (thickness) and in registration sensitivity (area).…”
Section: Other Types Of Semiconductor Detectorsmentioning
confidence: 93%
“…A further reason for obtaining a flat and representative sample surface was that the secondary X-rays from lighter elements often only emit from the top few micrometers of the sample. 14,15…”
Section: Methods Of Xrf Analysismentioning
confidence: 99%