2002
DOI: 10.1007/s003470100502
|View full text |Cite
|
Sign up to set email alerts
|

Zerkleinerung humaner Linsenkerne mittels Waterjet

Abstract: Intraocular use of the waterjet with direct effect of the stream with these pressures is not justifiable. Instruments for waterjet phacoemulsification should be developed which pose no danger to the corneal endothelium and lens capsule.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
2
0
1

Year Published

2004
2004
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 0 publications
0
2
0
1
Order By: Relevance
“…Early use of waterjet dissection has been reported in liver and kidney surgery. 10,30,31,34,35,52 Subsequently, waterjet dissection was used in orthopedic procedures, 8,9,16,41,48 urological and hepatic surgery, 2,45,56 parotid surgery, 18,47 ophthalmological surgery, 6,18,19,[53][54][55] with endovascular techniques, 20 and in thoracoabdominal surgery. 15,17 The first application of waterjet dissection in neurosurgery was reported by Terzis et al 51 in 1989.…”
mentioning
confidence: 99%
“…Early use of waterjet dissection has been reported in liver and kidney surgery. 10,30,31,34,35,52 Subsequently, waterjet dissection was used in orthopedic procedures, 8,9,16,41,48 urological and hepatic surgery, 2,45,56 parotid surgery, 18,47 ophthalmological surgery, 6,18,19,[53][54][55] with endovascular techniques, 20 and in thoracoabdominal surgery. 15,17 The first application of waterjet dissection in neurosurgery was reported by Terzis et al 51 in 1989.…”
mentioning
confidence: 99%
“…With the instrumentation developed in recent years, phacoemulsification surgery (PE) is considered the gold standard for cataract treatment. 1 Corneal endothelial cell loss occurs to a varying extent depending on the severity of surgical trauma, with these losses ranging from 16% to 67%. 2 Intraocular injection of a balanced salt solution and ophthalmic viscosurgical device (OVD) substances are used in PE to reduce tissue damage and corneal endothelial cell loss.…”
mentioning
confidence: 99%
“…Das Prinzip und die Funktionsweise von Aqualase wurde bereits mehrfach beschrieben [13,17]. Als mçgliche Vorteile werden aufgeführt: geringerer Endothelzellverlust [4], Minimierung der Gewebeerhitzung [1,8,25], bessere Nachstarprävention [26] und weniger Hinterkapselrupturen und Hornhautverbrennungen als mittels Ultraschall [17]. Mçglicherweise wäre mit dem Einsatz von Einmalhandgriffen die Aqualase -Technologie auch kostengünstiger als die Ultraschalltechnik.…”
unclassified