Considering the similar surgical success rates, and disadvantageous factors such as granulation formation, patient discomfort, and cost related to intubation, we recommend endoscopic dacryocystorhinostomy without intubation as the treatment of choice in cases of chronic epiphora due to postsaccal stenosis of the lacrimal drainage system.
We report the ocular manifestations of Alport syndrome and the surgical results in 4 patients. All 4 patients had anterior lenticonus; 2 also had posterior lenticonus in both eyes, 3 had flecked retina, and 1 had posterior polymorphous dystrophy. In both eyes of the 4 patients, phacoemulsification with intraocular lens (IOL) implantation was performed to treat anterior and posterior lenticonus. The postoperative visual acuity was excellent in all patients. We recommend phacoemulsification with IOL implantation as a safe and effective procedure in patients with lenticonus secondary to Alport syndrome.
Background: To evaluate the agreement between the optic nerve head (ONH) measurements obtained by spectral-domain optical coherence tomography/scanning laser ophthalmoscope (SD-OCT/SLO) and the Heidelberg retinal tomograph III (HRT-III), and to compare the ONH measurements of both devices in different glaucoma types. Methods: In a prospective study, 30 patients with primary open-angle glaucoma (POAG) and 30 patients with pseudoexfoliation glaucoma (PXG) were enrolled. All patients underwent SD-OCT/SLO and HRT-III evaluation of the ONH during the same visit. Agreement between measurements of SD-OCT/SLO and HRT-III were evaluated by determination of intraclass correlation coeficients. In addition, mean ONH measurements obtained with both devices were compared between POAG and PXG patient groups. Results: Mean SD-OCT/SLO measurements were greater than those of HRT-III, except for mean and maximum cup depth. Intraclass correlation coefficient values for disc area, rim area, cup area, cup/disc area ratio, mean cup depth and maximum cup depth were 0.367, 0.213, 0.632, 0.681, 0.775 and 0.661, respectively. No significant differences were found between ONH parameters of POAG and PXG patients as measured with both devices (p > 0.01). Conclusion: ONH measurements with SD-OCT/SLO and HRT-III did not show clinically acceptable agreement in glaucoma patients. This precludes interchangeable use of these measurements in clinical practice. PXG and POAG patient groups displayed similar ONH measurements with both devices.
Corneal viscoelastic properties are not significantly influenced in the late postoperative period by 23-G TSV which is a minimal invasive vitreoretinal surgical technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.