The Standards, Measurements and Testing Programme (formerly BCR) of the European Commission proposed a three-step sequential extraction procedure for sediment analysis, following extensive expert consultations and two interlaboratory studies. This scheme was recently used to certify the extractable trace element contents of a sediment reference material (CRM 601). Although this procedure offers a means to ensure the comparability of data in this field, some difficulties concerning the interlaboratory reproducibility still remain, and a new project is currently being conducted to determine the causes of poor reproducibility in the extraction scheme. The final objective of the project is the certification of new sediment and soil reference materials for their extractable contents of Cd, Cr, Cu, Ni, Pb and Zn. This paper presents the results of a small-scale interlaboratory study, which aimed to test a revised version of the extraction schemes by comparing the original and the modified protocols using the CRM 601 sample. This work offers an improvement to the BCR sequential extraction procedure through intercomparison exercises. This improved procedure will allow the obtaining of CRMs to validate analytical data in the analysis of soils and sediments, and it will also facilitate comparability of data in the European Union.
This paper provides additional data on a sewage sludge amended soil certified reference material, CRM 483, which was certified in 1997 for its EDTA and acetic acid extractable contents of some trace metals, following standardised extraction procedures. The additional work aimed to test the long-term stability of the material and the applicability of an improved version of the BCR three-step sequential extraction procedure on the sewage sludge amended soil (CRM 483). The paper demonstrates the CRM 483 long-term stability for EDTA and acetic acid extractable contents of Cd, Cr, Cu, Ni, Pb and Zn and gives the results (obtained in the framework of an interlaboratory study) for the extractable contents of the same elements in the CRM 483, following the BCR three-step sequential extraction scheme. The aqua regia extractable contents following the ISO 11466 Standard are also given. The data are given as indicative (not certified) values.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.