Paracetamol (acetaminophen) (PAR), caffeine (CAF) and tramadol hydrochloride (TRA) are important drugs widely used for many clinical purposes. Determination of their contents is of the paramount interest. In this respect, a quick, simple and sensitive isocratic RP-HPLC method with photodiode array detection was developed for the determination of paracetamol, caffeine and tramadol in pharmaceutical formulations. An improved sensitive procedure was also evolved for tramadol using a fluorescence detector system. A C18 column and a mobile phase constituted by methanol/phosphate were used. LODs were found to be 0.2 μg/mL, 0.1 μg/mL and 0.3 μg/mL for paracetamol, caffeine and tramadol hydrochloride, respectively, using photodiode-array detection. Alternatively, LOD for tramadol decreased to 0.1 μg/mL with the fluorescence detector. Other notable analytical figures of merit include the linear concentration ranges, 0.8–270 μg/mL, 0.4–250 μg/mL and 1.0–300 (0.2–40) μg/mL, for the same ordered analytes (including the fluorescence detector). The proposed method was successfully applied for the quantitative determination of the three drugs in tablet dosage forms.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.