IntroductionThe purpose of this study was to assess the structural characteristics of styloid process (SP) by cone-beam computed tomography (CBCT) examination in a patient population suffering from orofacial pain. The second aim was to assess the prevalence of elongated SP and its relation to gender, site and subjective symptoms in the study population.MethodsClinical and radiographic records of 208 patients were evaluated retrospectively. Radiological examinations including measurements of the structure, length, and medial angulations of SP were performed on CBCT images.ResultsOut of 208 patients, 96 (46%) had not-elongated SP, 28 (13%) had left side, 16 (8%) had right side, and 68 (33%) had bilateral elongation of SP. The patients with elongated SP had significantly decreased angle values. There were no statistically significant differences in length values of SP between males and females in both groups. Significantly increased prevalence of symptoms except headache was observed in patients with elongated SP.ConclusionsThis study presents the CBCT as an alternative method to CT or panoramic radiographs for the measurement and the assessment of the styloid process. Patients suffering from orofacial pain, who also had elongated SP, had increased rate of corresponding neurological complaints compared with non-elongated ones.
Alzheimer's disease (AD) is a multi-factorial neurodegenerative disorder that numerous factors have key properties in the development of this proteopathy. Glucose-6-phosphate dehydrogenase (G6PD) is the most common form of enzymopathy. We have examined G6PD enzyme activity levels in the serum of newly diagnosed AD patients compared with control subjects without dementia from the both sexes. Serum G6PD levels were found to be significantly higher (approximately two times) in AD patients compared to control geriatric subjects in both sexes. We have concluded that G6PD seems to play an integral role in the progress and/or prevention of AD.
Our results support the predictive value of spinal accessory nerve intraoperative neuromonitoring for determining shoulder function deterioration and activity restriction scores.
The purpose of this study was to determine the best predictive radiographic measurement method to identify the presence of osteoporosis and test the inter-observer and intra-observer reliability and validity of these methods in postmenopausal women. Materials and Methods: Ninety-two elderly female patients who presented with hip pain were included. Hip radiographs were used to determine the values of Singh index (SI), canal-to-calcar ratio (CCR), and cortical thickness index (CTI). All measurements were performed by two independent observers on two separate occasions, at least 4 weeks apart. Bone mineral density (BMD) was assessed by DEXA. In the first part of the analysis, reliability of the all measurement methods was tested. In the second part, correlation coefficient (Pearson r) was used to determine the relationship between the measurement methods and BMD. Finally ROC curve analysis was performed to determine the sensitivity, specificity, and threshold values for each radiographic measurement method. Results: Intra-observer reliability analysis of SI revealed kappa coefficient of 0.359 for observer A, and 0.224 for observer B. Inter-observer reliability analysis of SI revealed kappa coefficient of 0.070 for observer A and 0.051 for observer B. The intra-observer and inter-observer reliability was good and excellent for CTI and CCR for both observers (ICC: 0.920 and ICC: 0.936). There was no correlation between SI and BMD (p=0.818). On the other hand, there was a significant correlation between CTI and CCR and BMD (p=0.001). All measured indices were significantly different (p<0.05) between osteoporotic and non-osteoporotic patients. CTI value less than 0.3 or CCR value less than 0.47 reflects the presence of osteoporosis with 100% sensitivity and 98% specificity. Conclusion: SI is not reliable and do not correlate with BMD. However, both CTI and CCR showed good and excellent reliability, and each index correlated well with the real BMD values.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.