The changes in the autofluorescence characteristics of the bronchial tissue is of crucial interest as a cancer diagnostic tool. Evidence exists that this native fluorescence or autofluorescence of bronchial tissues changes when they turn dysplastic and to carcinoma in situ. There is good agreement that the lesions display a decrease of autofluorescence in the green region of the spectrum under illumination with violet-light, and a relative increase in the red region of the spectrum is often reported. Imaging devices rely on this principle to detect early cancerous lesions in the bronchi. Based on a spectroscopic study, an industrial imaging prototype is developed to detect early cancerous lesions in collaboration with the firm Richard Wolf Endoskope GmbH, Germany. A preliminary clinical trial involving 20 patients with this spectrally optimized system shows that the autofluorescence can help to detect most lesions that would otherwise have remained invisible to an experienced endoscopist under white light illumination. A systematic off line analysis of the autofluorescence images pointed out that real-time decisional functions can be defined to reduce the number of false positive results. Using this method, a positive predictive value (PPV) of 75% is reached using autofluorescence only. Moreover, a PPV of 100% is obtained, when combining the white light (WL) mode and the autofluorescence (AF) mode, at the applied conditions. Furthermore, the sensitivity is estimated to be twice higher in the AF mode than in WL mode.
Time-resolved measurements of tissue autofluorescence (AF) excited at 405 nm were carried out with an optical-fiber-based spectrometer in the bronchi of 11 patients. The objectives consisted of assessing the lifetime as a new tumor/normal (T/N) tissue contrast parameter and trying to explain the origin of the contrasts observed when using AF-based cancer detection imaging systems. No significant change in the AF lifetimes was found. AF bronchoscopy performed in parallel with an imaging device revealed both intensity and spectral contrasts. Our results suggest that the spectral contrast might be due to an enhanced blood concentration just below the epithelial layers of the lesion. The intensity contrast probably results from the thickening of the epithelium in the lesions. The absence of T/N lifetime contrast indicates that the quenching is not at the origin of the fluorescence intensity and spectral contrasts. These lifetimes (6.9 ns, 2.0 ns, and 0.2 ns) were consistent for all the examined sites. The fact that these lifetimes are the same for different emission domains ranging between 430 and 680 nm indicates that there is probably only one dominant fluorophore involved. The measured lifetimes suggest that this fluorophore is elastin.
This EMR method offers a promising approach in comparison with other options currently available. It appears to be superior in terms of the size of the resected specimen, the precision and regularity of the resection depth, and the accuracy of histological diagnosis with safety margins. Hemicircumferential EMRs have been shown to be safe in the sheep model. This new technique warrants further animal studies before being used for circumferential EMR in humans.
The response to photodynamic therapy (PDT) with the photosensitiser (PS) Tookad s was measured in the Syrian hamster cheek pouch model on normal mucosae and chemically induced squamous cell carcinoma. This PS is a palladium-bacteriopheophorbide presenting absorption peaks at 538 and 762 nm. The light dose, drug dose and drug injection-light irradiation times (DLI), ranging between 100 and 300 J cm À2 , 1 -5 mg kg À1 and 10 -240 min respectively, were varied and the response to PDT was analysed by staging the macroscopic response and by the histological examination of the sections of the irradiated cheek pouch. A fast time decay of the tissular response with drug dose of 1 -5 mg kg À1 was observed for DLI ranging from 10 to 240 min and for light doses of 100 -300 J cm À2 delivered at a light dose rate of 150 mW cm À2 . A significantly higher level of tissular response was observed for squamous cell carcinoma compared to normal tissue. Nevertheless, the threshold level of the drug -light dose for a detectable response was not significantly different in the tumoral vs normal tissue. The highest response at the shortest DLIs and the absence of measurable response at DLI larger than 240 min at light dose of 300 J cm À2 and drug dose of 5 mg kg À1 reveals the predominantly vascular effect of Tookad s . This observation suggests that Tookad s could be effective in PDT of vascularised lesions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.