Surveillance system [NNIS]) definitions for device-associated health care-associated infection, we collected prospective data from 155,358 patients hospitalized in the consortium's hospital ICUs for an aggregate of 923,624 days. Although device utilization in the developing countries' ICUs was remarkably similar to that reported from US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were markedly higher in the ICUs of the INICC hospitals: the pooled rate of central venous catheter (CVC)-associated bloodstream infections (BSI) in the INICC ICUs, 7.6 per 1000 CVC-days, is nearly 3-fold higher than the 2.0 per 1000 CVC-days reported from comparable US ICUs, and the overall rate of ventilator-associated pneumonia (VAP) was also far higher, 13.6 versus 3.3 per 1000 ventilator-days, respectively, as was the rate of catheter-associated urinary tract infection (CAUTI), 6.3 versus 3.3 per 1000 catheter-days, respectively. Most strikingly, the frequencies of resistance of Staphylococcus aureus isolates to methicillin (MRSA) (84.1% vs 56.8%, respectively), Klebsiella pneumoniae to ceftazidime or ceftriaxone (76.1% vs 27.1%, respectively), Acinetobacter baumannii to imipenem (46.3% vs 29.2%, respectively), and Pseudomonas aeruginosa to piperacillin (78.0% vs 20.2%, respectively) were also far higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 23.6% (CVC-associated bloodstream infections) to 29.3% (VAP).
Conventional indirect drug susceptibility testing of Mycobacterium tuberculosis with liquid medium is well established and offers time-saving and reliable results. This multicenter study was carried out to evaluate if drug susceptibility testing (DST) can be successfully carried out directly from processed smear-positive specimens (direct DST) and if this approach could offer substantial time savings. Sputum specimens were digested, decontaminated, and concentrated by the laboratory routine procedure and were inoculated in Bactec MGIT 960 as well as Lowenstein-Jensen (LJ) medium for primary isolation. All the processed specimens which were acid-fast bacterium (AFB) smear positive were used for setting up direct DST for isoniazid (INH) and rifampin (RIF). After the antimicrobial mixture of polymyxin B, amphotericin B, nalidixic acid, trimethoprim, and azlocillin (PANTA) was added, the tubes were entered in the MGIT 960 instrument using the 21-day protocol (Bactec 960 pyrazinamide [PZA] protocol). Results obtained by direct DST were compared with those obtained by indirect DST to establish accuracy and time savings by this approach. Of a total of 360 AFB smear-positive sputum specimens set up for direct DST at four sites in three different countries, 307 (85%) specimens yielded reportable results. Average reporting time for direct DST was 11 days (range, 10 to 12 days). The average time savings by direct DST compared to indirect DST, which included time to isolate a culture and perform DST, was 8 days (range, 6 to 9 days). When results of direct DST were compared with those of indirect DST, there was 95.1% concordance with INH and 96.1% with rifampin. These findings indicate that direct DST with the Bactec MGIT 960 system offers further time savings and is a quick method to reliably detect multidrug resistance (MDR) cases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.