Background: The maintenance of ridge volume following tooth extraction has gained more importance in the last few years. This clinical study aimed to assess the impact of autologous dentin particles mixed with injectable platelet-rich fibrin (i-PRF) on a sticky tooth mixture for socket preservation in terms of consecutive need for horizontal guided bone regeneration and histological findings. Methods: Eight extraction sockets in seven patients were included in this study. Autologous dentin particles were mixed with PRF, filled in the sockets, and covered with a cross-linked collagen membrane exposed to the oral cavity and fixated by crisscross sutures. An orthopantomogram was taken before the first surgical procedure and a CBCT prior to static computer-aided implant surgery. At the time of implant placement, cores were harvested with the aid of a trephine for histological examinations for every preserved socket. Results: No further horizontal GBR intervention was required in any cases, and the histological findings were unremarkable. The new bone was mostly cancellous and in direct contact with the remaining dentin granules. Conclusions: Within the limits of this clinical study, it may be concluded that this method is valuable for socket preservation and obtaining vital and good quality bone structure. The sticky tooth technique seems to be very efficient despite the more complex equipment.
The achievement of sufficient implant stability in poor quality bone seems to be a challenge. Most manufacturers develop special dental implants, which are claimed to show higher stability even in very soft bone. The aim of this experimental study was to compare two recently introduced dental implants with differing thread designs. A total of 11 implants of each group were inserted in the part of the fresh bovine ribs, corresponding to very soft bone. The primary stability was measured with resonance frequency analysis (RFA) and Periotest; the average of two measurements for each method and for each implant was taken and statistical analysis was applied. The highest stability values were obtained with the ICX Active Master implants, followed by the Conelog® Progressive-Line implants placed with the very soft bone protocol. The primary stability values of the Conelog® Progressive-Line implants inserted by the very soft bone protocol and the ICX Active Master implants placed with the standard protocol showed sufficient stability for immediate loading in low-density bone. Within the limitations of this study, the thread design of the implants and underdimensioned implant bed preparation seem to be effective for better primary stability in cancellous bone.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.