We intended to assess the humoral response induced by the Pfizer/BioNTech Comirnaty COVID-19 vaccine with commercially available immunoassays: anti-spike (S) IgG and IgM, and anti-nucleocapsid (N) IgG antibodies, over a 4-month course. One hundred subjects, including 15 COVID-19 convalescents, comprised the study cohort. The SARS-CoV-2 antibodies concentrations were measured on day 0′ and 10′, 20′, 30′, 60′, 90′, and 120′ after the first dose administration. Over the course of the study, 100% of the participants developed and sustained anti-SARS-CoV-2 S IgG antibodies. The highest concentration, exceeding the quantification range of the test (2080 BAU/mL), was reached by 67% of the subjects on day 30′. The concentration of the antibodies remained stable between days 30′ and 90′ but was followed by a significant decrease between days 90′ and 120′. The stronger and more persistent humoral response was noted for women. The COVID-19 convalescents developed higher antibody levels, particularly 10 days after the first Comirnaty dose. Twenty-three out of the eighty-five naïve vaccinees failed to develop a detectable IgM response. LIAISON® SARS-CoV-2 TrimericS IgG (DiaSorin S.p.A, Saluggia, Italy) may be useful in the assessment of the humoral response to the Comirnaty vaccine. In contrast, Abbott’s anti-S SARS-CoV-2 IgM has a limited utility in this context.
The immunoassays used to measure anti-spike SARS-CoV-2 antibodies are widely available on the market. However, their performance in COVID-19 vaccinees is not yet adequately assessed. Our study provides a head-to-head comparison of five methods: Abbott’s S1-RBD IgG, Roche’s S1-RBD total antibody, Euroimmun’s S1 IgG, and DiaSorin’s TrimericS IgG and S1/S2 IgG assays. Testing was performed in one hundred vaccinated subjects, at eight timepoints over eight months after vaccination. The results differed substantially between methods; however, they correlated strongly and demonstrated the individuals’ responses to both doses of vaccination and the waning of humoral immunity after eight months. Importantly, we encountered a high percentage of results above the assay-specific upper quantitation limit (UQL) for undiluted samples. This was the most pronounced for the Roche’s and Euroimmun’s assays. The Abbott’s assay showed the lowest percentage of results above the UQL. We also attempted to find a common way to establish antibody concentrations that might be classified as high. However, this resulted in between 10% and 100% of such results for different methods on day 240′. This highlights the need for an assay-specific approach for adjusting the cut-offs that may indicate COVID-19 immunity.
Objectives This study was aimed at providing some insights into the real-life performance of the commercial, clinically validated anti-SARS-CoV-2 antibody assays. Methods The residual, anonymized samples from 97 patients referred for anti-SARS-CoV-2 antibodies testing were included in the study. The initial assessment was performed with the Euroimmun ELISAs, followed by the assays provided by: NovaTec, Snibe, Vircell, Roche, Abbott and DiaSorin. The analyses of the results were performed separately for the antibodies of the early (IgM/IgA) and late (IgG) immune response. Results We observed a high variability of the results obtained with the investigated immunoassays. The fully concordant results were reported for only 57 out of 97 samples tested for IgG antibodies and for 34 out of 97 samples for IgM/IgA. The highest percentage of positive results was noted for the Euroimmun and Vircell ELISAs and the lowest for Novatec ELISAs. We proposed to distinguish true and false positive results based on the sum of positive results obtained with different methods. We arbitrarily considered reference positive samples reactive in at least half of the assays. The assay that proved to correlate the best with those reference results was the Roche electrochemiluminescence immunoassay. Conclusions The differences observed between immunoassays targeting the early phase antibodies were much more pronounced than between IgG assays, suggesting their lower value for clinical use. Our study also showed a high percentage of plausibly false (positive or negative) results obtained with ELISAs, which suggests their inferiority to the automated immunoassays.
This study pictures the humoral response of 100 vaccinees to Pfizer/BioNTech COVID-19 vaccine over a year, with particular focus on the influence of a booster shot administered around 10 months after the primary immunization. The response to the vaccination was assessed with Diasorin’s SARS-CoV-2 TrimericSpike IgG. Abbott’s SARS-CoV-2 Nucleocapsid IgG immunoassay was used to identify SARS-CoV-2 contact, even asymptomatic. In contrast to the gradual decline of the anti-spike IgG between 30 and 240 days after the first dose, an increase was noted between days 240 and 360 in the whole cohort. However, a statistically significant rise was seen only in boosted individuals, and this effect of the booster decreased over time. An increase was also observed in non-boosted but recently infected participants and a decrease was reported in non-boosted, non-infected subjects. These changes were not statistically significant. On day 360, a percentage of new SARS-CoV-2 infections was statistically lower in the boosted vs. non-boosted subgroups. The booster immunization is the most efficient way of stimulating production of anti-spike, potentially neutralizing antibodies. The response is additionally enhanced by the natural contact with the virus. Individuals with a low level of anti-spike antibodies may benefit the most from the booster dose administration.
ILUMINACJA PAŁACU TYSZKIEWICZÓW W WERYNIW artykule przedstawiono koncepcję iluminacji Pałacu Tyszkiewiczów w Weryni. Zaprezentowano autorski, komputerowy model obiektu architektonicznego, pomocny w wiarygodnym opracowaniu iluminacji. Projekt iluminacji Pałacu Tyszkiewiczów wykonany został z uwzględnieniem zasad techniki świetlnej i obowią-zujących norm. Do symulacji rzeczywistego efektu oświetlenia obiektu, zastosowano wizualizację fotorealistyczną modelu rozpatrywanego obiektu architektonicznego. Iluminacja obiektu to równieŜ jego promocja, dlatego powinna uwzględnić jego historyczny charakter i klimat, a takŜe realizowane funkcje i znaczenie. Prawidłowo zaprojektowane oświetlenie powinno skutkować podniesieniem walorów estetycznych obiektu. Wykorzystanie graficznej aplikacji komputerowej daje moŜliwość oceny róŜnych wariantów iluminacji pod względem przyjętych kryteriów iluminacji bez prób terenowych. Natomiast poprzez przeprowadzenie komputerowych obliczeń wielkości świetlnych, moŜna stwierdzić czy dana koncepcja spełnia ilościowe wymagania poziomów luminancji. Luminancja obok natęŜenia oświetlenia jest w większości przypadków wielkością normującą poziom wymagań oświetleniowych. Aby uzyskać poŜądany efekt oświetlenia, naleŜy zwrócić uwagę na typ elewacji budynku, stopień zabrudzenia, detale zdobnicze oraz warunki póź-niejszej eksploatacji instalacji oświetleniowej. Odpowiedni dobór sprzętu oświe-tleniowego jest szczególnie waŜny przy iluminacji budynków.Słowa kluczowe: źródła światła, iluminacja, luminancja, format IES.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.