The MB/BacT ALERT 3D System (MB/BacT) (Organon Teknika, Boxtel, The Netherlands) is a fully automated, nonradiometric system with a revised antibiotic supplement kit designed for the recovery of mycobacteria from clinical specimens. In a multicenter study, the recovery rate of acid-fast bacilli (AFB) and the mean time to their detection from clinical specimens was determined by using the MB/BacT system. Data were compared to those assessed by the radiometric BACTEC 460 system (B460) and by culture on Löwenstein-Jensen (L-J) solid medium. A total of 2,859 respiratory and extrapulmonary specimens were processed by the N-acetyl-L-cysteine (NALC)-NaOH method using two different concentrations of sodium hydroxide; 1.5% was adopted in study design A (1,766 specimens), and 1.0% was used in study design B (1,093 specimens). The contamination rates for MB/BacT were 4.6% (study design A) and 7.1% (study design B). One hundred seventy-nine mycobacterial isolates were detected by study design A, with 148 Mycobacterium tuberculosis complex (MTB) isolates and 31 nontuberculous mycobacteria (NTM) isolates. Overall recovery rates were 78.8% for MB/BacT (P ؍ 0.0049), 64.2% for L-J (P < 0.0001), and 87.1% for B460, whereas they were 84.5, 70.9, and 91.2%, respectively, for MTB alone. A total of 125 mycobacteria were detected by study design B, with 46 MTB and 79 NTM. Overall recovery rates by the individual systems were 57.6% (P ؍ 0.0002), 56.8% (P ؍ 0.0001), and 80% for MB/BacT, L-J, and B460, respectively, whereas the rates were 91.3, 78.3, and 97.8% for MTB alone. By study design A, the mean times to detection of smear-positive MTB, smear-negative MTB, and NTM were 11.5, 19.9, and 19.6 days, respectively, with the MB/BacT; 8.3, 16.8, and 16.6 days, respectively, with the B460; and 20.6, 32.1, and 27.8 days, respectively, with L-J medium. By study design B, the mean times were 15.1, 26.7, and 26 days with the MB/BacT; 11.7, 21.3, and 24.8 days with the B460; and 20.4, 28.7, and 28.4 days with L-J medium. Identification was attempted by probing (Accuprobe) MB/BacT-positive bottles within the first working day following instrument positive flag. Results were compared to those obtained in the B460 positive vials by the p-nitro-␣-acetylamino--hydroxypropiophenone (NAP) test (study design A) or by the Accuprobe assay (study design B). About 90% of MTB and 100% of NTM could be identified, showing turnaround times closely related to those obtained by combining B460 and the NAP test or the Accuprobe assay. In conclusion, even though recovery rates were shown to be lower than B460, especially for NTM, and contaminants were somewhat higher, MB/BacT represents a valuable alternative to the radiometric system, especially in those laboratories where disposal of radioactive waste is restricted. Finally, when AFB are cultured in nonradiometric liquid media, our data (detection times and bacterial overgrowth rates) suggest that decontamination with 1.5% NaOH may be more suitable than the standard NALC-NaOH.Although the introduction of a...
Two commercial assays detecting the presence of Mycobacterium tuberculosis complex in clinical specimens by rRNA target amplification (Gen-Probe Amplified M. tuberculosis Direct Test [AMTD]) and PCR (Amplicor) were evaluated. The tests were applied to 327 digested, decontaminated respiratory specimens collected from 236 patients. Results were compared with those of acid-fast staining and culture. The combination of culture and clinical diagnosis was considered the "gold standard." A total of 60 specimens were collected from 27 patients with a diagnosis of pulmonary tuberculosis. Thirteen of these specimens were from patients receiving standard antituberculosis therapy and therefore were not included in the comparison. Of the remaining 47 specimens, 33 were smear positive, 40 were culture positive, 45 were AMTD positive, and 39 were Amplicor positive. After resolution of discrepant results, the overall sensitivities, specificities, and positive and negative predictive values were 77, 100, 100, and 95 for staining; 87, 100, 100, and 97.4 for culture; 95.9, 98.9, 94, and 99.2 for AMTD; and 85.4, 99.6, 97.9, and 97.1 for Amplicor, respectively. Agreement between AMTD and Amplicor assay results was 96.8%. It is concluded that although both nucleic acid amplification methods are rapid and specific for the detection of M. tuberculosis complex in respiratory specimens, AMTD appeared to be more sensitive than Amplicor.
Two commercial assays that detect Mycobacterium tuberculosis complex (MTB) in clinical specimens by rRNA target amplification (AMTDII) and ligase chain reaction (LCx) were evaluated. The tests were applied to 457 respiratory (n = 273) and extrapulmonary (n = 184) specimens collected from 357 patients. The results were compared with those of acid-fast staining and culture. The combination of culture and clinical diagnosis was considered to be the “gold standard.” Seventy specimens were from patients with pulmonary tuberculosis and 28 specimens were from patients with extrapulmonary tuberculosis. After resolution of discrepant results, the overall sensitivities, specificities, and positive and negative predictive values for respiratory specimens were 92.8, 99.4, 98.5, and 97%, respectively, for AMTDII and 75.7, 98.8, 96.4, and 90.5%, respectively, for LCx. With extrapulmonary specimens, the overall sensitivities, specificities, and positive and negative predictive values were 78.6, 99.3, 95.6, and 96.2%, respectively, for AMTDII and 53.6, 99.3, 93.7, and 92.1%, respectively, for LCx. The level of agreement between AMTDII and LCx assay results was 78.2%. We conclude that although both nucleic acid amplification methods are rapid and specific for the detection of MTB in clinical specimens, AMTDII is significantly more sensitive than LCx with both respiratory (P = 0.005) and extrapulmonary (P = 0.048) specimens.
The isolation of Mycobacterium malmoense has for a long time been restricted to few countries of Northern Europe; reports from countries other than Sweden, Great Britain and Finland are rare and the first Italian case report has been published in 1995. Since 1988, however, fifteen strains of M. malmoense have been isolated in Italy, eleven of which in the last two years; of these, ten appeared clinically significant on the basis of medical records. The susceptibility of the strains and the role of high performance liquid chromatography of cell wall mycolic acids for a reliable identification are discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.