Two rock hyraxes ( Procavia capensis), from the Chattanooga Zoo, were submitted separately for autopsy at the University of Tennessee Veterinary Medical Center. The first was a 4-y-old intact female that died without premonitory signs and the second was a 10-y-old intact male that was euthanized because of severe renal disease. Microscopically, the lungs of both hyraxes had multifocal-to-coalescing, <1-mm diameter aggregates of epithelioid macrophages separated by streams of fibrous tissue. Macrophages contained intracytoplasmic, clear, acicular, birefringent crystals. Transmission electron microscopy and energy-dispersive x-ray spectroscopy findings on the lung samples were consistent with silica crystal deposition. The hyraxes had been housed together on commercially sourced play sand composed of 99–99.5% quartz, a crystalline silica polymorph. The microscopic findings, transmission electron microscopy, and energy-dispersive x-ray spectroscopy of the intrahistiocytic crystals, in addition to the history of exposure to crystalline silica, were consistent with pulmonary silicosis. Pulmonary silicosis has not been reported previously in rock hyraxes, to our knowledge.
OBJECTIVE
To evaluate the level of agreement (LOA) between direct and oscillometric blood pressure (BP) measurements and the ability of oscillometric measurements to accurately detect hypotension in anesthetized chimpanzees (Pan troglodytes).
ANIMALS
8 captive, adult chimpanzees.
PROCEDURES
During prescheduled annual examinations, each chimpanzee underwent general anesthesia and patient monitoring for their examination, echocardiography for a concurrent study, and measurement of direct BP with the use of tibial artery catheterization and oscillometry with the use of a cuff placed around a brachium and a cuff placed around the second digit of the contralateral forelimb for the present study. Bland-Altman plots were generated to compare results for direct and oscillometric BP measurements. Mean bias and 95% LOAs were calculated for oscillometric measurements of systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and mean arterial pressure (MAP) for each cuff site. Sensitivity and specificity in detecting hypotension were also determined for each cuff site.
RESULTS
There were 74 paired direct and brachial oscillometric measurements of each, SAP, MAP, and DAP and 66 paired direct and digit oscillometric measurements of each, SAP, MAP, and DAP. Only brachial oscillometric measurements of MAP had adequate sensitivity (78%) and specificity (95%) to accurately detect hypotension, and this technique also had the least mean bias (0.8 mm Hg; 95% LOA, –29 to 31 mm Hg).
CONCLUSIONS AND CLINICAL RELEVANCE
Results indicated that brachial oscillometric measurement of MAP provided reasonable agreement with tibial arterial direct MAP measurement and performed well in diagnosing hypotension in anesthetized chimpanzees.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.