Regional differences in rabbit atrial repolarization were investigated using a conventional microelectrode technique. A more rapid phase 1 repolarization (lower phase 1 amplitude) was seen in the left atrial (LA) roof area compared with the right atrial (RA) roof area: 54 +/- 10 vs. 82 +/- 6 mV at 1,000 ms (P < 0.001). In addition, action potential duration at 40 mV above the resting potential (APD40) was shorter in LA and was associated with a slower phase 3 repolarization rate. Furthermore, the recovery time constant of phase 1 amplitude at 500 ms was 0.9 +/- 0.2 s in LA and 3.5 +/- 1.5 s in RA (P < 0.001). Pacing cycle lengths (2,000, 1,500, 1,000, 800, and 500 ms) modulated phase 1 amplitude, APD40, and phase 3 rate in both regions. 4-Aminopyridine (4-AP; 1 mM), a selective transient outward current (I(to)) blocker, abolished cycle length dependence of the above action potential parameters and diminished the differences in electrophysiological properties between the two regions. 4-AP also flattened the restitution curve of phase 1 amplitude in both regions. In conclusion, the findings suggest that the different kinetics of I(to) play an important role in regional differences of atrial repolarization.
Background There is a relative paucity of data linking inappropriate implantable cardioverter-defibrillator (ICD) shocks to adverse clinical outcomes. Objective To examine the association between inappropriate ICD shocks and mortality or heart transplantation in a large population cohort. Design, setting, patients A cohort study which included all subjects who underwent ICD implantation between 1998 and 2008 and were followed up at our institution. Main outcome measures Multivariable Cox regression analyses were conducted to investigate the effect of inappropriate shocks on the risk of death and heart transplantation. Appropriate and inappropriate ICD therapies were modelled as time-dependent covariates. Results A total of 1698 patients were included. During a median follow-up of 30 months, there were 246 (14.5%) deaths and 42 (2.5%) heart transplants. The incidence of inappropriate shocks was 10% at 1 year and 14% at 2 years. In the adjusted model, inappropriate shocks were not associated with death or transplantation (HR=0.97, 95% CI 0.70 to 1.36, p value=0.873). In contrast, appropriate shocks were associated with adverse outcomes (HR=3.11, 95% CI 2.41 to 4.02, p value<0.001). The lack of association between inappropriate shocks and outcomes persisted for those with severely impaired left ventricular function (ejection fraction <30%) and for those receiving multiple inappropriate treatments. Conclusions In this study, we observed no association between inappropriate ICD shocks and increased mortality or heart transplantation, even among those with severely impaired cardiac function. These findings question whether inappropriate ICD shocks lead to adverse outcomes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.