The ability to record accessory atrioventricular (AV) pathway activation consistently may be uniquely beneficial in improving pathway localization, identifying anatomic relations, and providing insight into unusual conduction properties. For the purpose of recording left AV accessory pathway activation, an electrode catheter was specially designed for use in the coronary sinus. The orthogonal catheter has three sets of four electrodes spaced evenly around the circumference. Electrograms were recorded at low gain (<1 cm/mV) between adjacent electrodes on the same set (interelectrode distance, 1.5 mm, center to center). This provides a recording dipole perpendicular to the atrioventricular groove to enhance recording of accessory pathway activation while miinimizing overlapping atrial or ventricular potentials. The orthogonal electrode catheter was used in the electrophysiological study of 48 consecutive patients with 59 left AV accessory pathways. The catheter could be advanced along the coronary sinus beyond the site of earliest retrograde atrial activation in 49 of the 59 accessory pathways. Activation potentials were recorded from 45 of the 49 (92%) accessory pathways accessible to the catheter (5 of 5 anterior, 8 of 8 anterolateral, 15 of 16 lateral, 5 of 5 posterolateral, 5 of 5 posterior, and 7 of 10 posteroseptal). Accessory pathway potentials were validated by dissociating them from both atrial and ventricular activation by programmed-stimulation techniques. During surgery, accessory pathway potentials were identfied from orthogonal catheter electrodes in the coronary sinus in 14 of 16 accessory pathways (12 patients). Epicardial mapping confirmed the location of the accessory pathway, and direct pressure over the orthogonal catheter electrode that recorded the accessory pathway potential resulted in transient conduction block in nine of the 14 accessory pathways. Orthogonal electrode maps of the coronary sinus identified an oblique course in 39 of 45 recorded accessory pathways. Thirty-two of 38 left free-wall accessory pathways were oriented with atrial insertion 4-30 mm (median, 14 mm) proximal (posterior) to the ventricular insertion. In the remaining six free-wail accessory pathways, the lateral excursion could not be determined because either only the atrial end of the accessory pathway was recorded or activation of multiple pathway fibers prevented tracking of individual strands. The seven recorded posteroseptal pathways exhibited accessory pathway potentials throughout an 8-18-mm (median, 10 mm) length of the proximal coronary sinus, but fiber orientation was difficult to determine. We conclude that left AV accessory pathway activation can be recorded consistently from orthogonal catheter electrodes in the coronary sinus. Direct accessory pathway recordings revealed an oblique fiber orientation and may provide more precise loalization for surgical or catheter ablation. (Circulation 1988;78:598-610) E a lectrophysiological studies in patients with of accessory atrioventricular (AV) pathways b...
Regional differences in rabbit atrial repolarization were investigated using a conventional microelectrode technique. A more rapid phase 1 repolarization (lower phase 1 amplitude) was seen in the left atrial (LA) roof area compared with the right atrial (RA) roof area: 54 +/- 10 vs. 82 +/- 6 mV at 1,000 ms (P < 0.001). In addition, action potential duration at 40 mV above the resting potential (APD40) was shorter in LA and was associated with a slower phase 3 repolarization rate. Furthermore, the recovery time constant of phase 1 amplitude at 500 ms was 0.9 +/- 0.2 s in LA and 3.5 +/- 1.5 s in RA (P < 0.001). Pacing cycle lengths (2,000, 1,500, 1,000, 800, and 500 ms) modulated phase 1 amplitude, APD40, and phase 3 rate in both regions. 4-Aminopyridine (4-AP; 1 mM), a selective transient outward current (I(to)) blocker, abolished cycle length dependence of the above action potential parameters and diminished the differences in electrophysiological properties between the two regions. 4-AP also flattened the restitution curve of phase 1 amplitude in both regions. In conclusion, the findings suggest that the different kinetics of I(to) play an important role in regional differences of atrial repolarization.
Background There is a relative paucity of data linking inappropriate implantable cardioverter-defibrillator (ICD) shocks to adverse clinical outcomes. Objective To examine the association between inappropriate ICD shocks and mortality or heart transplantation in a large population cohort. Design, setting, patients A cohort study which included all subjects who underwent ICD implantation between 1998 and 2008 and were followed up at our institution. Main outcome measures Multivariable Cox regression analyses were conducted to investigate the effect of inappropriate shocks on the risk of death and heart transplantation. Appropriate and inappropriate ICD therapies were modelled as time-dependent covariates. Results A total of 1698 patients were included. During a median follow-up of 30 months, there were 246 (14.5%) deaths and 42 (2.5%) heart transplants. The incidence of inappropriate shocks was 10% at 1 year and 14% at 2 years. In the adjusted model, inappropriate shocks were not associated with death or transplantation (HR=0.97, 95% CI 0.70 to 1.36, p value=0.873). In contrast, appropriate shocks were associated with adverse outcomes (HR=3.11, 95% CI 2.41 to 4.02, p value<0.001). The lack of association between inappropriate shocks and outcomes persisted for those with severely impaired left ventricular function (ejection fraction <30%) and for those receiving multiple inappropriate treatments. Conclusions In this study, we observed no association between inappropriate ICD shocks and increased mortality or heart transplantation, even among those with severely impaired cardiac function. These findings question whether inappropriate ICD shocks lead to adverse outcomes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.