Overall, strong levels of evidence exist for iPhone and scoliometer measurements, with a high to very high reliability and moderate to very high validity. Moderate levels of evidence exist for scoliometer with mathematical formula and clinical examination with moderate and low validity, respectively. Limited evidence exists for aesthetic tools TRACE and AI and 2D photography. These results indicate there are accurate and reproducible anthropometric measures that are inexpensive and applicable in therapy settings to assess postural asymmetry; however, these only exist for measurement in the transverse plane, despite 3D characteristics of AIS. Further research is required into an inexpensive and easily administered method that can assess postural asymmetry in all anatomical planes.
AIMTo investigate the reliability and concurrent validity of the Baseline® Body Level/Scoliosis meter for adolescent idiopathic scoliosis postural assessment in three anatomical planes.METHODSThis is an observational reliability and concurrent validity study of adolescent referrals to the Orthopaedic department for scoliosis screening at Karolinska University Hospital, Stockholm, Sweden between March-May 2012. A total of 31 adolescents with idiopathic scoliosis (13.6 ± 0.6 years old) of mild-moderate curvatures (25° ± 12°) were consecutively recruited. Measurement of cervical, thoracic and lumbar curvatures, pelvic and shoulder tilt, and axial thoracic rotation (ATR) were performed by two trained physiotherapists in one day. The intraclass correlation coefficient (ICC) was used to determine the inter-examiner reliability (ICC2,1) and the intra-rater reliability (ICC3,3) of the Baseline® Body Level/Scoliosis meter. Spearman’s correlation analyses were used to estimate concurrent validity between the Baseline® Body Level/Scoliosis meter and Gold Standard Cobb angles from radiographs and the Orthopaedic Systems Inc. Scoliometer.RESULTSThere was excellent reliability between examiners for thoracic kyphosis (ICC2,1 = 0.94), ATR (ICC2,1 = 0.92) and lumbar lordosis (ICC2,1 = 0.79). There was adequate reliability between examiners for cervical lordosis (ICC2,1 = 0.51), however poor reliability for pelvic and shoulder tilt. Both devices were reproducible in the measurement of ATR when repeated by one examiner (ICC3,3 0.98-1.00). The device had a good correlation with the Scoliometer (rho = 0.78). When compared with Cobb angle from radiographs, there was a moderate correlation for ATR (rho = 0.627).CONCLUSIONThe Baseline® Body Level/Scoliosis meter provides reliable transverse and sagittal cervical, thoracic and lumbar measurements and valid transverse plan measurements of mild-moderate scoliosis deformity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.