High-resolution scanning electron microscopy (HR-SEM) with backscattered electrons (BSE) under a low accelerating voltage provided images with compositional information about Pt nano-particles with a diameter of approximately 6 nm that were dispersed in mesoporous silica (SBA-15). The dispersion of Pt nano-particles in mesoporous silica was investigated using the BSE imaging method in combination with the broad ion beam (BIB) cross-section fabrication technique.
Studies in ultra low voltage condition have been reporting the interesting phenomena such as the mismatch of the proportional relationship between the image contrast and the atomic number[1], the possibility that the information source size of BSE is shallower than that of SE[2], some of which don't follow the general logic to interpret the SEM image based on the traditional SEM principles.In the study, we set our motivation to consider the mechanism to explain such an interesting phenomena particularly happened at the ultra low voltage situation. At first we gathered a set of SE and BSE images simultaneously at ultra low voltage condition from various kinds of specimen. Second, we compared the SE and BSE image to investigate the difference. A simulation results by CASINO [3] was also applied for the theoretical consideration. In the study the recent cold FE-SEM (Hitachi SU8000) is used. The SEM is offering the SE/BSE filtering capability even at ultra low voltage condition as shown in Fig.1. Fig.2 shows SE and BSE imaging of the Poly Si surface at the landing voltage of 100V. In SE image, distribution of the residue is clearly confirmed as a dark colored contrast, which is accomplished by the static potential detection with high sensitivity. In BSE image, approximately 1nm height topographic information was enhanced so that the fine surface morphology both on Poly Si surface and the residue were clearly observed. Fig.3 shows the electron scattering simulation results on Si substrate by landing voltage of 100V. BSE scattering depth was around 0.9nm, which imply the spatial resolution for Z direction, was less than 1nm at 100V BSE signal. In case PE scattering region is extremely shallow like as imaging by the landing voltage of 100V, all SE is emitted without any loss. SE will be emitted from almost the entire PE scattering region so that its information source is likely to be deeper than BSE. Nevertheless, the SE image at ultra low voltage condition has the topmost surface information due to keeping the extremely shallower PE scattering region than conventional SE imaging condition.We also report the our examination results to acquire the spatial resolution of SE and BSE.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.