Determination of the half‐value layer (HVL) and quarter‐value layer (QVL) values is not an easy task in X‐ray computed tomography (CT), because a nonrotating X‐ray tube must be used, which requires the assistance of service engineers. Therefore, in this study, we determined the accuracy of the lead‐covered case method, which uses X‐rays from a rotating X‐ray tube, for measuring the HVL and QVL in CT. The lead‐covered case was manufactured from polystyrene foam and a 4 mm thick lead plate. The ionizing chamber was placed in the center of the case and aluminum filters were placed 15 cm above the aperture surface. Aperture widths of 1.0, 2.0, and 3.0 cm for a tube voltage of 110 kV and an aperture width of 2.0 cm for the tube voltages of 80 and 130 kV were used to measure exposure doses. The results of the HVL and QVL were compared with those of the conventional nonrotating method. A 2.0 cm aperture was believed to be adequate, because of its small differences in the HVL and QVL in the nonrotating method and its reasonable exposure dose level. When the 2.0 cm aperture was used, the lead‐covered case method demonstrated slightly larger HVLs and QVLs (0.03‐0.06 mm for the HVL and 0.2‐0.4 mm for the QVL) at all the tube voltage settings. However, the differences in the effective energy were 0.1‐0.3 keV; therefore, it could be negligible in an organ‐absorbed dose evaluation and a quality assurance test for CT.PACS numbers: 87.57.‐s; 87.57.Q‐; 87.57.uq
This study aimed to evaluate the property of small dosimeters used for measuring eye lens doses for medical staff during fluoroscopic examination. Dose linearity, energy dependence, and directional dependence of scattered X-rays were evaluated for small radiophotoluminescence glass dosimeters (RPLDs), those with a tin filter (Sn-RPLDs), and small optically stimulated luminescence dosimeters (OSLDs). These dosimeters were pasted on radioprotective glasses, and accumulated air kerma was obtained after irradiating the X-rays to a patient phantom. Strong correlations existed between fluoroscopic time and accumulated air kerma in all types of dosimeters. The energy dependence of Sn-RPLD and OSLD was smaller than that of RPLD. The relative dose value of the OSLD gradually decreased as the angle of the OSLD against the scattered X-rays was larger or lower than the right angle in the horizontal direction. The ranges of relative dose values of RPLD and Sn-RPLD were larger than that of OSLD in the vertical direction. The OSLDs showed lower doses than the RPLDs and Sn-RPLDs, especially on the right side of the radioprotective glasses. These results showed that RPLDs, Sn-RPLDs, and OSLDs had different dosimeter properties, and influence measured eye lens doses for the physician, especially on the opposite side of the patient.
It is important to reduce the dose received by medical staffs. The purpose of this study was to evaluate the effect of protective curtain and the property of small optically stimulated luminescence (OSL) dosimeters used for ambient dose measurement in fluoroscopy. The property of small OSL dosimeters was investigated in terms of uniformity, changing fluoroscopy time and polymethyl methacrylate (PMMA) thickness, and angular dependence. Paper pipes were assembled in glid shape and ambient dose was investigated by using small OSL dosimeters that were put on them with and without protective curtain. Air kerma was investigated by small OSL dosimeters that were put on a head phantom at the position of eyes. Dose response of small OSL dosimeters was independent of fluoroscopy time and PMMA thickness, so it is appropriate to measure ambient dose by small OSL dosimeters. In relation to ambient dose, there was significant difference with and without protective curtain (p<0.001, paired-t-test). These air kerma on the head phantom were reduced to approximately 20% by attaching protective curtain. In order to reduce the dose received by operators, it is desirable to use protective curtain.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.