Advances in computer vision have substantially improved our ability to analyze the structure and mechanics of the heart. In comparison, our ability to observe and analyze cardiac electrical activities is much limited. The progress to computationally reconstruct cardiac current sources from noninvasive voltage data sensed on the body surface has been hindered by the ill-posedness and the lack of a unique solution of the reconstruction problem. Common L2- and L1-norm regularizations tend to produce a solution that is either too diffused or too scattered to reflect the complex spatial structure of current source distribution in the heart. In this work, we propose a general regularization with Lp-norm (1 < p < 2) constraint to bridge the gap and balance between an overly smeared and overly focal solution in cardiac source reconstruction. In a set of phantom experiments, we demonstrate the superiority of the proposed Lp-norm method over its L1 and L2 counterparts in imaging cardiac current sources with increasing extents. Through computer-simulated and real-data experiments, we further demonstrate the feasibility of the proposed method in imaging the complex structure of excitation wavefront, as well as current sources distributed along the postinfarction scar border. This ability to preserve the spatial structure of source distribution is important for revealing the potential disruption to the normal heart excitation.
Noninvasive cardiac electrophysiological (EP) imaging aims to mathematically reconstruct the spatiotemporal dynamics of cardiac sources from body-surface electrocardiographic (ECG) data. This ill-posed problem is often regularized by a fixed constraining model. However, a fixed-model approach enforces the source distribution to follow a pre-assumed structure that does not always match the varying spatiotemporal distribution of actual sources. To understand the model-data relation and examine the impact of prior models, we present a multiple-model approach for volumetric cardiac EP imaging where multiple prior models are included and automatically picked by the available ECG data. Multiple models are incorporated as an Lp-norm prior for sources, where p is an unknown hyperparameter with a prior uniform distribution. To examine how different combinations of models may be favored by different measurement data, the posterior distribution of cardiac sources and hyperparameter p is calculated using a Markov Chain Monte Carlo (MCMC) technique. The importance of multiple-model prior was assessed in two sets of synthetic and real-data experiments, compared to fixed-model priors (using Laplace and Gaussian priors). The results showed that the posterior combination of models (the posterior distribution of p) as determined by the ECG data differed substantially when reconstructing sources with different sizes and structures. While the use of fixed models is best suited in situations where the prior assumption fits the actual source structures, the use of an automatically adaptive set of models may have the ability to better address model-data mismatch and to provide consistent performance in reconstructing sources with different properties.
Objective Noninvasive cardiac electrophysiological (EP) imaging techniques rely on anatomically-detailed heart-torso models derived from high-quality tomographic images of individual subjects. However, anatomical modeling involves variations that lead to unresolved uncertainties in the outcome of EP imaging, bringing questions to the robustness of these methods in clinical practice. In this study, we design a systematic statistical approach to assess the sensitivity of EP imaging methods to the variations in personalized anatomical modeling. Methods We first quantify the variations in personalized anatomical models by a novel application of statistical shape modeling. Given the statistical distribution of the variation in personalized anatomical models, we then employ unscented transform to determine the sensitivity of EP imaging outputs to the variation in input personalized anatomical modeling. Results We test the feasibility of our proposed approach using two of the existing EP imaging methods: epicardial-based electrocardiographic imaging and transmural electrophysiological imaging. Both phantom and real-data experiments show that variations in personalized anatomical models have negligible impact on the outcome of EP imaging. Conclusion This study verifies the robustness of EP imaging methods to the errors in personalized anatomical modeling and suggests the possibility to simplify the process of anatomical modeling in future clinical practice. Significance This study proposes a systematic statistical approach to quantify anatomical modeling variations and assess their impact on EP imaging, which can be extended to find a balance between the quality of personalized anatomical models and the accuracy of EP imaging that may improve the clinical feasibility of EP imaging.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.