A new method for the selective determination of laminin-5 concentration using a biosensor and surface plasmon resonance imaging (SPRI) technique is presented. A biosensor based on the specific interaction of laminin-5 with rabbit polyclonal antibody was constructed. The analytically useful dynamic response range of the biosensor is between 0.014 and 0.1 ng mL−1. The detection limit is 4 pg mL−1. The potential influence of interferences on the SPRI signal was investigated, and the high selectivity of the biosensor was confirmed. In order to demonstrate the potential application of the biosensor, laminin-5 concentration in blood plasma was determined. The results were compared with the laminin-5 concentration obtained by the commercial enzyme-linked immunosorbent assay (ELISA) kit. A comparison of results from healthy donors obtained by SPRI measurement and ELISA indicates that they are close and shows good agreement with the data reported in the literature. The plasma samples of bladder cancer patients gave higher concentration measured with specific biosensor than by ELISA assay. The study shows the clear difference in concentration of laminin-5 in healthy humans and patients with bladder cancer. Extensive clinical studies using the newly developed method can result in an increase in the use of laminin-5 as a potential cancer marker.Electronic supplementary materialThe online version of this article (doi:10.1007/s00216-016-9621-x) contains supplementary material, which is available to authorized users.
The aim of this study was to measure the serum AMH (anti-Mullerian hormone) concentrations in a group of boys with or without cryptorchidism, evaluation of karyotypes, testicular position, morphology, and major length of the undescended testes. Fifty boys who were 1–4 years old (median = 2.4 years) with unilateral cryptorchidism were evaluated. All of them underwent orchidopexy in 2010. Prior to the procedure, all of the subjects had undergone karyotyping to exclude chromosomal abnormalities. Fifty healthy boys within the same age range (median = 2.1 years) admitted for planned inguinal hernia repair in 2010, served as controls. Blood samples were collected, while obtaining blood for standard laboratory tests routinely performed before the surgeries. Medians of AMH in boys with cryptorchidism were lower than in boys with inguinal hernia and differed significantly between two groups. Undescended testes were generally found in superficial inguinal pouch (n = 46), in two cases were noted to be in the external ring of the inguinal canal, and in another two instances, in the abdominal cavity. The major lengths of the undescended testes were smaller in comparison to the testes positioned normally (mean of 1 cm vs. a mean of 1.5 cm, respectively). In nine of the cases, the testes had turgor deficit, a drop shape, with epididymides that were small, dysplastic, and separated from the testis. The authors found that AMH was lower in boys with unilateral cryptorchidism (also found to have smaller testis) when compared with the control group.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.