Acute urinary retention is a common problem in the emergency department. Patients can present in significant distress, necessitating the placement of a urinary catheter. Foley catheter placement can be difficult to accomplish depending on the etiology of the retention and the degree of the obstruction. In the case presented here, we used ultrasound guidance, a guidewire, and a Foley catheter to successfully relieve a patient’s urinary retention after multiple failed attempts.
Background:
Prior research has revealed that cervical collars elevate intracranial pressure (ICP) in patients with traumatic brain injury. Two recent small studies evaluated the change in optic sheath nerve diameter (ONSD) measured by ultrasound as a proxy for ICP following cervical collar placement in healthy volunteers.
Objective:
We sought to validate the finding that ONSD measured by ultrasound increases after cervical collar placement within an independent data set.
Methods:
This was a prospective, crossover study involving volunteers. Participants were randomized to either have the ONSD measured first without a cervical collar or initially with a cervical collar. Two sonographers performed independent ONSD diameter measurements. Continuous data were analyzed by matched-paired
t
-tests. Alpha was set at 0.05. The primary outcome parameter was the overall mean difference between ONSD measurements with the cervical collar on and off. Multiple linear regression was performed to examine the relationship between variables and the primary outcome parameter.
Results:
There were 30 participants enrolled in the study. Overall mean ONSD for participants without the collar was 0.365 ± 0.071 cm and with the collar was 0.392 ± 0.081 cm. The mean change in ONSD for participants with and without the collar was 0.026 ± 0.064 cm (95% confidence interval of difference: 0.015–0.038;
P
< 0.001). Multiple regression analysis did not identify any variables associated with the variation in ONSD observed for collar versus noncollar.
Conclusions:
We confirmed that ONSD does vary by a measurable amount with placement of a rigid cervical collar on healthy volunteers when assessed by ultrasound.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.