SummaryFunctional dyspepsia (FD) and irritable bowel syndrome (IBS) are frequent disorders affecting quality of life. They often require long-term treatment. Abdominal symptoms of both disorders can overlap, making differential diagnosis and treatment challenging. The extracts of the herbal combination preparation STW 5 (Iberogast®) exert pharmacological effects in different gastrointestinal regions and can address symptoms of both FD and IBS. This review summarizes safety and efficacy data of 12 clinical trials using STW 5 in FD and IBS since 1990. Double-blind and randomized studies versus placebo or active control found statistically significant effects of STW 5 on patients’ symptoms with a comparable efficacy to a standard prokinetic. Non-interventional and retrospective studies confirmed these effects. Various studies evaluated the tolerability profile of STW 5: the incidence of adverse drug reactions was 0.04 %. The worldwide spontaneous reporting system confirmed this profile. STW 5 has a favorable tolerability which is relevant for long-term treatment.
BackgroundWater displacement leg volumetry is a highly reproducible method, allowing the confirmation of efficacy of vasoactive substances. Nevertheless errors of its execution and the selection of unsuitable patients are likely to negatively affect the outcome of clinical studies in chronic venous insufficiency (CVI).DiscussionPlacebo controlled double-blind drug studies in CVI were searched (Cochrane Review 2005, MedLine Search until December 2007) and assessed with regard to efficacy (volume reduction of the leg), patient characteristics, and potential methodological error sources. Almost every second study reported only small drug effects (≤ 30 mL volume reduction). As the most relevant error source the conduct of volumetry was identified. Because the practical use of available equipment varies, volume differences of more than 300 mL - which is a multifold of a potential treatment effect - have been reported between consecutive measurements. Other potential error sources were insufficient patient guidance or difficulties with the transition from the Widmer CVI classification to the CEAP (Clinical Etiological Anatomical Pathophysiological) grading.SummaryPatients should be properly diagnosed with CVI and selected for stable oedema and further clinical symptoms relevant for the specific study. Centres require a thorough training on the use of the volumeter and on patient guidance. Volumetry should be performed under constant conditions. The reproducibility of short term repeat measurements has to be ensured.
Background
Dialyzers shall be designed to efficiently eliminate uremic toxins during a dialysis treatment, given that the accumulation of small and middle molecular weight uremic solutes is associated with increased mortality risk of patients with end-stage renal disease. In the present study we investigated the novel FX CorAL dialyzer with a modified membrane surface for the performance during online-hemodiafiltration in a clinical setting.
Methods
comPERFORM was a prospective, open, controlled, multi-centric, interventional, cross-over study with randomized treatment sequences. It randomized stable patients receiving regular post-dilution online hemodiafiltration (HDF) to FX CorAL 600 (Fresenius Medical Care Deutschland GmbH), xevonta Hi 15 (B. Braun), and ELISIO 150H (Nipro), each for one week. The primary outcome was β2-microglobulin removal rate (ß2-m RR) during online-HDF. Secondary endpoints were RR and/or clearance of ß2-m and other molecules. Albumin removal over time was an exploratory endpoint. Non-inferiority and superiority of FX CorAL 600 vs. competitors were tested.
Results
52 patients were included and analyzed. FX CorAL 600 showed the highest ß2-m RR (75.47%), followed by xevonta Hi 15 (74.01%) and ELISIO 150H (72.70%). Superiority to its competitors was statistically significant (P = 0.0216 and P < 0.0001, respectively). Secondary endpoints related to middle molecules affirmed these results. FX CorAL 600 demonstrated the lowest albumin removal up to 60 min, and its sieving properties changed less over time than with competitors.
Conclusions
FX CorAL 600 efficiently removed middle and small molecules and was superior to the two comparators in ß2-m RR. Albumin sieving kinetics point to a reduced formation of a secondary membrane.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.