Inhalation is a mainstay for treatment of asthma, and lung deposition can be seen as a surrogate marker for the ensuing clinical effects. Not only absolute lung deposition, but also its variability is of interest, as it indicates the range of expected lung deposition in an individual patient when prescribing the drug and the expected day-to-day variability when using it. A literature survey found 71 studies with relevant information on lung deposition and its variability. Further characteristics of the studies, such as if the subjects were healthy or asthmatics, adults or children, and what device that was used, were noted. In all, 187 data points were included. Variability in lung deposition was depicted as a function of mean lung deposition; for the entire data set and for subsets thereof. Independent of device type or subject category high lung deposition was associated with low relative variability and vice versa. Using a published throat deposition model, the observed correlation of lung deposition variability to mean lung deposition could be explained as being determined largely by the extent of and variability in throat deposition. We hypothesize that throat deposition is the major determinant for lung deposition of an inhaled aerosol, and its absolute variability will largely be determined by the absolute variability in throat deposition. The relative variability in lung deposition will therefore tend to be high for low lung deposition and low for high lung deposition. Consequently, low relative variability in lung deposition can only be attained if high lung deposition is achieved.
A new cascade impactor has been designed specifically for pharmaceutical inhaler testing. This impactor, called the Next Generation Pharmaceutical Impactor (NGI), has seven stages and is intended to operate at any inlet flow rate between 30 and 100 L/min. It spans a cut size (D50) range from 0.54-microm to 11.7-microm aerodynamic diameter at 30 L/min and 0.24 microm to 6.12 microm at 100 L/min. The aerodynamics of the impactor follow established scientific principles, giving confident particle size fractionation behavior over the design flow range. The NGI has several features to enhance its utility for inhaler testing. One such feature is that particles are deposited on collection cups that are held in a tray. This tray is removed from the impactor as a single unit, facilitating quick sample turn-around times if multiple trays are used. For accomplishing drug recovery, the user can add up to approximately 40 mL of an appropriate solvent directly to the cups. Another unique feature is a micro-orifice collector (MOC) that captures in a collection cup extremely small particles normally collected on the final filter in other impactors. The particles captured in the MOC cup can be analyzed in the same manner as the particles collected in the other impactor stage cups. The user-friendly features and the aerodynamic design principles together provide an impactor well suited to the needs of the inhaler testing community.
We could show that the amount of drug escaping filtration in a realistic throat model under realistic delivery conditions predicts the typical total lung deposition in trained healthy adult subjects in the absence of significant exhaled mass. We could further show that by using combinations of throat models and flow profiles that represent realistic deviations from the typical case, variations in ex-cast deposition reflect between-subject variation in lung deposition. Further, we have demonstrated that ex-cast deposition collected either by a simple filter or by a cascade impactor operated at a fixed flow rate using a mixing inlet, to accommodate a variable flow profile through the inhaler, predicts equally well the lung deposited dose. Additionally, the ex-cast particle size distribution measured by this method may be relevant for predicting exhaled fraction and regional lung deposition by computational models.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.