In an aqueous solution the phospholipids dimyristoyl-sn-glycero-3-phosphocholine (DMPC) and 1,2-dihexanoyl-sn-glycero-3-phosphocholine (DHPC) self-assemble to form thermo-responsive non-Newtonian fluids (i.e., pseudogels) in which small temperature changes of 5-6 °C decrease viscosity dramatically. This characteristic is useful for sieving-based electrophoretic separations (e.g., of DNA), as the high viscosity of linear sieving additives, such as linear polyacrylamide or polyethylene oxide, hinders the introduction and replacement of the sieving agent in microscale channels. Advantages of utilizing phospholipid pseudogels for sieving are the ease with which they are introduced into the separation channel and the potential to implement gradient separations. Capillary electrophoresis separations of DNA are achieved with separation efficiencies ranging from 400,000 to 7,000,000 theoretical plates in a 25 μm i.d. fused silica capillary. Assessment of the phospholipid pseudogel with a Ferguson plot yields an apparent pore size of ~31 nm. Under isothermal conditions, Ogston sieving is achieved for DNA fragments smaller than 500 base pairs, whereas reptation-based transport occurs for DNA fragments larger than 500 base pairs. Nearly single base resolution of short tandem repeats relevant to human identification is accomplished with 30 min separations using traditional capillary electrophoresis instrumentation. Applications that do not require single base resolution are completed with faster separation times. This is demonstrated for a multiplex assay of biallelic single nucleotide polymorphisms relevant to warfarin sensitivity. The thermo-responsive pseudogel preparation described here provides a new innovation to sieving-based capillary separations.
Microwave energy has been used to rapidly heat food and drinks for decades, in addition to assisting other chemical reactions. However, only recently has microwave energy been applied in microfluidic systems to heat solution in reaction chambers, in particular, the polymerase chain reaction (PCR). One of the difficulties in developing microwave-mediated heating on a microchip is the construction of the appropriate architecture for delivery of the energy to specific micro-areas on the microchip. This work employs commercially-available microwave components commonly used in the wireless communications industry to generate a microwave signal, and a microstrip transmission line to deliver the energy to a 1 μL reaction chamber fabricated in plastic microdevices. A model was developed to create transmission lines that would optimally transmit energy to the reaction chamber at a given frequency, minimizing energy usage while focusing microwave delivery to the target chamber. Two different temperature control methods were demonstrated, varying microwave power or frequency. This system was used to amplify a fragment of the lambda-phage genome, thereby demonstrating its potential for integration into a portable PCR system.
We report an improved separation method for the isolation of sperm cells from dilute, "large volume" samples containing female DNA using beadassisted acoustic trapping. In an enclosed glass−PDMS−glass (GPG) resonator, we exploit a three-layer microfluidic architecture to generate "trapping nodes" in ultrasonic standing waves. We investigate the dependence of trapping efficiency on particle concentration for both sperm cells and polymeric beads. After determination of the critical concentration of polymeric beads required to seed the trapping event, sperm cells in dilute solution are trapped as a result of the enhanced secondary radiation force (SRF). Sperm-cell-containing samples with volumes up to 300 μL and cell concentrations as low as ∼10 cells/μL are amenable to effective trapping in the presence of an abundance of female DNA in solution. Complete processing of samples is accomplished with separation of the female and male fractions within 15 min. We demonstrate that the collected fractions are amenable to subsequent DNA extraction, short tandem repeat PCR, and the generation of STR profiles for the isolated sperm cells.
Biochemical techniques, such as the polymerase chain reaction (PCR), can take up to 3.5 h for completion using a commercial bench-top instrument, creating a bottleneck in sample preparation processes. PCR has been successfully adapted to microfluidic devices, reducing the time needed to as little as 7-10 min. Recently, a trend in the field is to use alternative substrates, such as poly(methyl methacyrlate) (PMMA), for the fabrication of microfluidic devices. PMMA has several advantages over more expensive substrates including rigidity without fragility, disposability, and it is easy to fabricate, using techniques such as hot embossing or CO 2 laser ablation. Here, we report the fabrication of PMMA microdevices to explore their effectiveness for PCR amplification. Several types of PMMA microdevices were fabricated using a CO 2 laser ablation system, with two or three PMMA layers of different thicknesses. Bonding of the microdevices was significantly improved through the use of a grid system etched into the device, allowing for trapped air to escape, eliminating leakage. Using infrared thermal cycling, the ramping rates were determined to be dependent on the thickness of the PMMA used in fabrication, allowing for customization of cycling conditions. Further reduction of the thermal mass by isolation of the chambers provided a significant increase in the heating and cooling rates (up to 6.19 ( ± 0.32 • C s −1 ) and −7.99 ( ± 0.06 • C s −1 ), respectively). Bubble formation, a chronic problem in microfluidic systems in general and problematic during the heating phase of PCR, was minimized through the use of a biocompatible adhesive/manifold combination to seal the reservoirs. Finally, successful PCR amplification was demonstrated with both a fragment from the β-globin gene and 15 tetra-nucleotide repeat regions with a sex-typing marker in a conventional STR kit with the latter facilitated by the dynamic coating of the fluidic architecture with poly(ethylene glycol) (PEG).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.