A solution-based inductively coupled plasma optical emission spectrometric (ICP-OES) method is described for elemental analysis with relative expanded uncertainties on the order of 0.1% relative. The single-element determinations of 64 different elements are presented, with aggregate performance results for the method and parameters for the determination of each element. The performance observed is superior to that previously reported for ICP-OES, resulting from a suite of technical strategies that exploit the strengths of contemporary spectrometers, address measurement and sample handling noise sources, and permit rugged operation with small uncertainty. Taken together, these strategies constitute high-performance ICP-OES.
Several measurements and calculations were performed to illustrate the differences that can be observed in the determination of exposure rate or ambient dose equivalent rate used for testing radiation detection systems against consensus standards. The large variations observed support our recommendation that better consistency in the test radiation fields can be achieved by specifying the source activity and testing distance instead of the field strength.
The pre-irradiation combustion (PC) of samples to liberate iodine, followed by trapping the iodine on charcoal and quantifying the element by neutron activation analysis (NAA), has been used at the National Institute of Standards and Technology for the determination of iodine in biological materials. The applicability of this technique to numerous environmental and dietary matrices is illustrated by analysis of a range of certified reference materials (CRMs) and a powdered grass material that was prepared as an in-house reference material (RM). Because of the combustion step involved, samples with low or no fat content (e.g., cereal products, selected botanical specimens, and nonfat milk powder) and inorganic materials (e.g., coal fly ash and dried sediments) are more suited for analysis by this method. In general, the results for several types of samples obtained by this method agreed with those obtained by a second radiochemical (R) NAA, as well as by a third method using inductively coupled plasma mass spectrometry (ICP-MS). PC-NAA is a useful technique for determining iodine in biological and environmental samples, especially for verification of iodine results obtained from other methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.