Abstract. There are many methods for human-computer interface. Recently, many researchers are studying about brain-signal. This is because not only the disabled can use a computer by their thought without their limbs but also it is convenient to general people. In this paper, we propose a platform for the real time electroencephalogram(EEG) and magnetoencephalography(MEG) analysis system. The signals on the scalp are so weak. Thus, the signals must be amplified by the amplifier. Filters are used to filter the incoming continuous signal before it is sampled by the analog-to-digital converter(ADC). The filtered EEG and MEG are analyzed and compacted by using FFT and JPEG2000, respectively. The platform is easy to reuse because of its simple block architecture and is implemented as a single chip on the Xilinx Virtex5 FPGA development board.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.