BackgroundAdherence to prescribed medications is a key dimension of healthcare quality. The aim of this large population-based study was to evaluate self-reported medication adherence and to identify factors linked with poor adherence in patients with type 2 diabetes in France.MethodologyThe ENTRED study 2007, a French national survey of people treated for diabetes, was based on a representative sample of patients who claimed reimbursement for oral hypoglycaemic agents and/or insulin at least three times between August 2006 and July 2007, and who were randomly selected from the database of the two main National Health Insurance Systems. Medication adherence was determined using a six-item self-administered questionnaire. A multinomial polychotomous logistic regression model was used to identify factors associated with medication adherence in the 3,637 persons with type 2 diabetes.Principal FindingsThirty nine percent of patients reported good medication adherence, 49% medium adherence and 12% poor adherence. The factors significantly associated with poor adherence in multivariate analysis were socio-demographic factors: age <45 years, non-European geographical origin, financial difficulties and being professionally active; disease and therapy-related factors: HbA1c>8% and existing diabetes complications; and health care-related factors: difficulties for taking medication alone, decision making by the patient only, poor acceptability of medical recommendations, lack of family or social support, need for information on treatment, reporting no confidence in the future, need for medical support and follow-up by a specialist physician.ConclusionsIn a country with a high level of access to healthcare, our study demonstrated a substantial low level of medication adherence in type 2 diabetic patients. Better identification of those with poor adherence and individualised suitable recommendations remain essential for better healthcare management.
PurposePoint spread function (PSF) reconstruction improves spatial resolution throughout the entire field of view of a PET system and can detect smaller metastatic deposits than conventional algorithms such as OSEM. We assessed the impact of PSF reconstruction on quantitative values and diagnostic accuracy for axillary staging of breast cancer patients, compared with an OSEM reconstruction, with emphasis on the size of nodal metastases.MethodsThis was a prospective study in a single referral centre in which 50 patients underwent an 18F-FDG PET examination before axillary lymph node dissection. PET data were reconstructed with an OSEM algorithm and PSF reconstruction, analysed blindly and validated by a pathologist who measured the largest nodal metastasis per axilla. This size was used to evaluate PET diagnostic performance.ResultsOn pathology, 34 patients (68 %) had nodal involvement. Overall, the median size of the largest nodal metastasis per axilla was 7 mm (range 0.5 – 40 mm). PSF reconstruction detected more involved nodes than OSEM reconstruction (p = 0.003). The mean PSF to OSEM SUVmax ratio was 1.66 (95 % CI 1.01 – 2.32). The sensitivities of PSF and OSEM reconstructions were, respectively, 96 % and 92 % in patients with a largest nodal metastasis of >7 mm, 60 % and 40 % in patients with a largest nodal metastasis of ≤7 mm, and 92 % and 69 % in patients with a primary tumour ≤30 mm. Biggerstaff graphical comparison showed that globally PSF reconstruction was superior to OSEM reconstruction. The median sizes of the largest nodal metastasis in patients with nodal involvement not detected by either PSF or OSEM reconstruction, detected by PSF but not by OSEM reconstruction and detected by both reconstructions were 3, 6 and 16 mm (p = 0.0064) respectively. In patients with nodal involvement detected by PSF reconstruction but not by OSEM reconstruction, the smallest detectable metastasis was 1.8 mm.ConclusionAs a result of better activity recovery, PET with PSF reconstruction performed better than PET with OSEM reconstruction in detecting nodal metastases ≤7 mm. However, its sensitivity is still insufficient for it to replace surgical approaches for axillary staging. PET with PSF reconstruction could be used to perform sentinel node biopsy more safely in patients with a primary tumour ≤30 mm and with unremarkable PET results in the axilla.Electronic supplementary materialThe online version of this article (doi:10.1007/s00259-014-2689-7) contains supplementary material, which is available to authorized users.
BackgroundUntil now, FISH has been the gold standard technique to identify HER2 amplification status in ambiguous cases of breast cancer. Alternative techniques have been developed to increase the capacities of investigating HER2 amplification status. The aims of this multicenter study in a large series of breast cancer patients were to prospectively compare the level of performance of CISH, SISH, and qPCR alternative techniques on paraffin-embedded core biopsies with “gold standard FISH” for evaluation of HER2 amplification status.MethodsThis study was performed on 840 cases scored by immunohistochemistry (IHC): 0=317 (38%), 1+=183 (22%), 2+=109 (13%), 3+=231 (27%). Each of the 15 French centers participating in the study analyzed 56 breast carcinoma cases diagnosed on fixed paraffin-embedded core biopsies. HER2 amplification status was determined by commercially available FISH used as the reference technique with determination of the HER2/CEN17 ratio or HER2 copy number status. The alternative techniques performed on the same cases were commercially available SISH or CISH and a common qPCR method especially designed for the study including a set of 10 primer pairs: 2 for HER2 (exons 8 and 26), 5 to evaluate chromosome 17 polysomy TAOK1, UTP6, MRM1, MKS1, SSTR2 and 3 for diploidy control TSN, LAP3 and ADAMTS16.ResultsThe concordance between IHC and FISH was 96% to 95% based on the HER2/CEN17 ratio (n=766) or HER2 copy number (n=840), respectively. The concordance of the alternative techniques with FISH was excellent: 97% and 98% for SISH (498 and 587 cases), 98% and 75% for CISH (108 and 204 cases) and 95% and 93% (699 and 773 cases) for qPCR based on the HER2/CEN17 ratio or HER2 copy number, respectively. Similarly, sensitivity ranged from 99% to 95% for SISH, 100% to 99% for CISH and 89% to 80% for qPCR. The concordance with FISH (ratio) in the 2+ cases was 89% for SISH, 100% for CISH and 93% for qPCR.ConclusionThese alternative techniques showed an excellent concordance with FISH in core biopsies allowing their use in routine clinical practice. This newly designed qPCR on paraffin-embedded core biopsies deserves special attention, as it is reliable, easy to perform and less expensive than ISH tests.
A standardless semi-quantitative method for wavelength dispersive spectrometry ( WDS) electron probe microbeam analysis was developed with a view to simplifying the analytical procedure required with this apparatus. Based on spectrum acquisition, this method is a way to obtain the sample composition in a short time with the advantages of the WDS system and maintaining reasonable accuracy. To this end, three specific algorithms were designed. The first algorithm was constructed to find automatically all the elements present in the sample and to select the appropriate X-ray line for each element. It needs to index automatically, with a good confidence level, all the peaks which are detected. The second was constructed to convert the X-ray peak area from the measured spectrum into X-ray peak intensity (normally used in WDS procedures) with a Gaussian function which is governed both by the characteristics of the crystal and by the X-ray line itself. This is essential to prevent any underestimation of the concentration due to the measurement of truncated peaks related to low sampling frequencies, and to improve the counting statistics by using all the information given by the spectrum. Finally, the sample composition was obtained with the calculation of the absolute intensity of the selected line which takes into account the spectrometer efficiency.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.