The purpose of this study was to define the surface properties of prepared titanium (Ti) disks, which served as a model system, and to contrast the biologic response of MG63 cells exposed to Ti disks with different levels of surface roughness. The surface properties interact with each other, resulting in a change of other surface qualities in addition to roughness due to the surface roughening procedure. The machined Ti disks were roughened by sandblasting and electric glow discharging. The surface properties of the Ti specimens were inspected through a comprehensive surface analysis. MG63 cell behaviors were compared along with cell number, alkaline phosphatase (ALP) activity, Runx2 gene expression, and type I collagen production. Statistics were evaluated, using analysis of variance (ANOVA). The sandblasted Ti disks demonstrated well-controlled surface roughness features and meaningful average roughness ranges, including the surface roughness of the "modern" microrough implant, used clinically. With increasing Ti surface roughness, the cell number decreased, while the ALP activity, type I collagen production, and Runx2 gene expression increased significantly. The rougher the Ti surface was, the sooner the Runx2 gene was expressed. Based on these results, we suggest that the microrough Ti surfaces of the 1-3 mum range may contribute effectively to osteogenic differentiation and proliferation in MG63 cells.
PURPOSEThis study compared the accuracy of an abutment-framework (A-F) taken with open tray impression technique combining cementon crown abutments, a metal framework and resin cement to closed tray and resin-splinted open tray impression techniques for the 3-implant definitive casts. The effect of angulation on the accuracy of these 3 techniques was also evaluated.MATERIAL AND METHODSThree definitive casts, each with 3 linearly positioned implant analogs at relative angulations 0, 30, and 40 degrees, were fabricated with passively fitted corresponding reference frameworks. Ten impressions were made and poured, using each of the 3 techniques on each of the 3 definitive casts. To record the vertical gap between reference frameworks and analogs in duplicate casts, a light microscope with image processing was used. Data were analyzed by two-way analysis of variance and the Tukey test.RESULTSThe open tray techniques showed significantly smaller vertical gaps compare to closed tray technique (P < .05). The closed tray and the resin-splinted open tray technique showed significantly different vertical gaps according to the angulation of implant (P < .05), but the A-F impression technique did not (P > .05).CONCLUSIONThe accuracy of the A-F impression technique was superior to that of conventional techniques, and was not affected by the angulation of the implants.
PURPOSE.The aim of the present study was to evaluate the accuracy of three techniques for correction of cast implant bars. MATERIALS AND METHODS. Thirty cast implant bars were fabricated on a metal master model. All cast implant bars were sectioned at 5 mm from the left gold cylinder using a disk of 0.3 mm thickness, and then each group of ten specimens was corrected by gas-air torch soldering, laser welding, and additional casting technique. Three dimensional evaluation including horizontal, vertical, and twisting measurements was based on measurement and comparison of (1) gap distances of the right abutment replica-gold cylinder interface at buccal, distal, lingual side, (2) changes of bar length, and (3) axis angle changes of the right gold cylinders at the step of the post-correction measurements on the three groups with a contact and non-contact coordinate measuring machine. One-way analysis of variance (ANOVA) and paired t-test were performed at the significance level of 5%. RESULTS. Gap distances of the cast implant bars after correction procedure showed no statistically significant difference among groups. Changes in bar length between pre-casting and post-correction measurement were statistically significance among groups. Axis angle changes of the right gold cylinders were not statistically significance among groups. CONCLUSION. There was no statistical significance among three techniques in horizontal, vertical and axial errors. But, gas-air torch soldering technique showed the most consistent and accurate trend in the correction of implant bar error. However, Laser welding technique, showed a large mean and standard deviation in vertical and twisting measurement and might be technique-sensitive method. [ J Adv Prosthodont 2014;6:39-45]
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.