Parietal cell antibodies were present in 12% of 272 Peruvians presenting for endoscopy. Gender, age, socioeconomic status, ethnic background (Peruvian versus Japanese), and altitude at which the patient lived were not associated with the presence of parietal cell antibodies. No significant relationship could be shown between the presence of parietal cell antibodies and either Helicobacter pylori infection or gastric lesions, including chronic atrophic gastritis. Loss of proper gastric glands was significantly more common in patients who had H. pylori infection than in those in whom no H. pylori was found on biopsy (78 of 114 (85%) versus 14 of 36 (39%); p = 0.002). Our data suggest that, although parietal cell antibodies are present in third-world populations, they are unrelated to H. pylori infection and that pathologic changes associated with this infection are not mediated by the action of parietal cell antibodies on the cells of the stomach.
Nuevas técnicas nos están permitiendo migrar de la técnica de cera perdida colado por centrifugado convencio- nal (CPCC) a técnicas como la cera perdida colado por inducción (CPCI). Objetivos: Comparar la discrepancia marginal e interna de cofias unitarias de aleación Cobalto-Cromo (Co-Cr) sobre una línea de terminación cham- fer, confeccionadas con dos técnicas: CPCC y CPCI, determinando cual técnica tuvo mejor adaptación marginal e interna. Material y Métodos: Se fabricaron13 cofias metálicas unitarias de aleación Co-Cr para cada técnica a evaluar. Se utilizó la réplica de silicona para evaluar las discrepancias marginales e internas, cada muestra fue seccionada en cruz en sentido vestíbulo-palatino y en sentido mesio-distal, luego con un estéreomicroscopio se evaluó la zona cervical, axial y oclusal. Resultados: Se evaluó los supuestos de normalidad con la prueba de Shapiro-Wilk. Los análisis estadísticos fueron la prueba t de Student y U Mann-Whitney. La CPCI obtuvo una menor discrepancia marginal e interna en comparación con la CPC pero no se encontró diferencias estadísti- camente significativas (p>0,05) entre ambas técnicas. Conclusiones: Aunque en la mayoría de los puntos de evaluación las cofias realizadas mediante la CPCI presento mejores valores de adaptación marginal e interna en comparación con la CPCC estos resultados sólo son valores descriptivos que no fueron concluyentes, ya que en la mayoría de los puntos evaluados no existió diferencia estadísticamente significativa (p>0,05). Observamos que la mayoría de los valores de ambas técnicas se encuentran dentro del rango clínicamente aceptable.
We have examined endoscopic clinic patients in three widely different geographic regions of Peru (the coast, the Sierra of the Andes Mountains, and the Amazon jungle) for the presence of Helicobacter pylori infection associated with active gastritis. The overall rates of infection were high (80% or greater) in all three zones and rates for men were approximately 10% higher than for women in the same zone. Men and women in the Sierra and jungle areas had significantly higher rates of infection than did those on the coast. There was no significant difference between the three populations with respect to the relationship between infection and grade of gastritis.
Nuevas tecnologías nos han permitido migrar de la técnica de cera perdida colada por centrifugado (CPC) a la fabricación aditiva como la fusión selectiva por láser (SLM), proporcionando una mejor adaptación marginal e interna. Objetivos: Comparar la discrepancia marginal e interna en cofi as unitarias de Co-Cr sobre 2 líneas de terminación: chamfer y bisel, fabricadas con la CPC y SLM, determinando cual tuvo mejor adaptación marginal e interna. Material y Métodos: Se tuvo 4 grupos de estudio: CPC chamfer (n=13), CPC bisel (n=13), SLM chamfer (n=13) y SLM bisel (n=13). Para evaluar la discrepancia marginal e interna se usó el método de la réplica en silicona, seccionando primero en sentido vestíbulo-palatino (V-P) y segundo en sentido mesio-distal (M-D). Se midió las zonas cervical, axial y oclusal con un estéreo microscopio a 40X. Resultados: Se evaluó los supuestos de normalidad con la prueba de Shapiro-Wilk, y el análisis estadístico fue con las pruebas t de Student y U Mann-Whitney. La menor discrepancia marginal fue para la SLM chamfer con promedios menores de 24,70±10,29 μm en el corte V-P y de 21,82±5,94 μm en el corte M-D, seguido por la SLM bisel en el corte V-P de 34,12±16,23 μm y en el corte M-D de 35,34±8,91 μm. La CPC bisel en el corte V-P fue de 27,17±21,11 μm y en el corte M-D de 47,91±16,77 μm y para la CPC chamfer en el corte V-P fue de 89,65±58,39 μm y en el corte M-D de 91,72±67,13 μm; la diferencia fue estadísticamente signifi cativa solo para las cofi as de SLM chamfer comparándolas con la CPC chamfer. En la discrepancia interna los valores en los 4 grupos no tuvieron diferencias estadísticas. Conclusiones: Según los valores, la mejor adaptación marginal fue para la SLM chamfer, seguida por la SLM bisel, CPC bisel y la CPC chamfer. En cuanto a la adaptación interna, los valores no fueron concluyentes para decir que técnica fue mejor, pero se logró mejor adaptación en la zona axial que la zona oclusal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.