PETbox4 is a new, fully tomographic bench top PET scanner dedicated to high sensitivity and high resolution imaging of mice. This manuscript characterizes the performance of the prototype system using the National Electrical Manufacturers Association (NEMA) NU 4–2008 standards, including studies of sensitivity, spatial resolution, energy resolution, scatter fraction, count-rate performance and image quality. The PETbox4 performance is also compared with the performance of PETbox, a previous generation limited angle tomography system. PETbox4 consists of four opposing flat-panel type detectors arranged in a box like geometry. Each panel is made by a 24 × 50 pixelated array of 1.82 × 1.82 × 7mm bismuth germanate (BGO) scintillation crystals with a crystal pitch of 1.90mm. Each of these scintillation arrays is coupled to two Hamamatsu H8500 photomultiplier tubes via a glass light guide. Volumetric images for a 45 × 45 × 95 mm field of view (FOV) are reconstructed with a maximum likelihood expectation maximization (ML-EM) algorithm incorporating a system model based on a parameterized detector response. With an energy window of 150–650 keV, the peak absolute sensitivity is approximately 18% at the center of FOV. The measured crystal energy resolution ranges from 13.5% to 48.3% full width at half maximum (FWHM), with a mean of 18.0%. The intrinsic detector spatial resolution is 1.5mm FWHM in both transverse and axial directions. The reconstructed image spatial resolution for different locations in the FOV ranges from 1.32mm to 1.93 mm, with an average of 1.46 mm. The peak noise equivalent count rate for the mouse-sized phantom is 35 kcps for a total activity of 1.5 MBq (40 µCi) and the scatter fraction is 28%. The standard deviation in the uniform region of the image quality phantom is 5.7%. The recovery coefficients range from 0.10 to 0.93. In comparison to the first generation two panel PETbox system, PETbox4 achieves substantial improvements on sensitivity and spatial resolution. The overall performance demonstrates that the PETbox4 scanner is suitable for producing high quality images for molecular imaging based biomedical research.
HiPET is a recently developed prototype preclinical PET scanner dedicated to high sensitivity and high resolution molecular imaging. The HiPET system employs a phoswich depth of interaction (DOI) detector design, which also allows identification of the large majority of the cross layer crystal scatter (CLCS) events. This work evaluates its performance characteristics following the National Electrical Manufacturers Association (NEMA) NU4-2008 protocol. The HiPET consists of twenty flat panel type detectors arranged in two rings. The inner diameter is 160 mm and the axial field of view (FOV) is 104 mm. Each detector is comprised of two layers of phoswich scintillator crystal arrays, a tapered, pixelated glass lightguide and a multi anode photomultiplier tube (MAPMT). The front (gamma ray entrance) layer is a 48 × 48 pixelated cerium doped lutetium yttrium orthosilicate (LYSO) scintillator array with individual crystals measuring 1.01 × 1.01 × 6.1 mm. The back (towards the PMT) layer is a 32 × 32 pixelated bismuth germanate (BGO) scintillator array with individual crystals measuring 1.55 × 1.55 × 8.9 mm. For energy windows of 250–650 keV and 350–650 keV, the peak absolute sensitivity at the center of the FOV was 13.5% and 10.4% including CLCS events, and 11.8% and 8.9% excluding CLCS events, respectively. The average detector energy resolution derived by averaging the individual crystal spectra was 11.7% ± 1.4% for LYSO and 17.0% ± 1.4% for BGO. The 3D ordered-subsets expectation maximization (OSEM) reconstructed image of a point source in air, ranged from 0.73 mm to 1.19 mm, with an average value of 0.93 ± 0.09 mm at all measured locations. The peak noise equivalent count rate (NECR) and scatter fraction were 179 kcps at 12.4 MBq and 6.9% for the mouse-sized phantom, and 63 kcps at 11.3 MBq and 18.3% for the rat-sized phantom. For the NEMA image quality phantom, the uniformity was 5.8%, and the spillover ratios measured in the water- and air-filled cold region chambers were 0.047 and 0.044, respectively. The recovery coefficients (RC) ranged from 0.31 to 0.92. These results and in vivo evaluation demonstrate that the HiPET can achieve high quality molecular imaging for biomedical applications.
A new phoswich detector is being developed at the Crump Institute, aiming to provide improvements in sensitivity, and spatial resolution for PET. The detector configuration is comprised of two layers of pixelated scintillator crystal arrays, a glass light guide and a light detector. The annihilation photon entrance (top) layer is a 48 × 48 array of 1.01 × 1.01 × 7 mm3 LYSO crystals. The bottom layer is a 32 × 32 array of 1.55 × 1.55 × 9 mm3 BGO crystals. A tapered, multiple-element glass lightguide is used to couple the exit end of the BGO crystal array (52 × 52 mm2) to the photosensitive area of the Position Sensitive Photomultiplier Tube (46 × 46 mm2), allowing the creation of flat panel detectors without gaps between the detector modules. Both simulations and measurements were performed to evaluate the characteristics and benefits of the proposed design. The GATE Monte Carlo simulation indicated that the total fraction of the cross layer crystal scatter (CLCS) events in singles detection mode for this detector geometry is 13.2%. The large majority of these CLCS events (10.1% out of 13.2%) deposit most of their energy in a scintillator layer other than the layer of first interaction. Identification of those CLCS events for rejection or correction may lead to improvements in data quality and imaging performance. Physical measurements with the prototype detector showed that the LYSO, BGO and CLCS events were successfully identified using the delayed charge integration (DCI) technique, with more than 95% of the LYSO and BGO crystal elements clearly resolved. The measured peak-to-valley ratios (PVR) in the flood histograms were 3.5 for LYSO and 2.0 for BGO. For LYSO, the energy resolution ranged from 9.7% to 37.0% full width at half maximum (FWHM), with a mean of 13.4 ± 4.8%. For BGO the energy resolution ranged from 16.0% to 33.9% FWHM, with a mean of 18.6 ± 3.2%. In conclusion, these results demonstrate that the proposed detector is feasible and can potentially lead to a high spatial resolution, high sensitivity and DOI PET system.
Abstract-The design of an imaging system capable of detecting both high-energy -rays and optical wavelength photons is underway at the UCLA Crump Institute for Molecular Imaging. This system, which we call optical PET (OPET), will be capable of noninvasively and repeatedly imaging small animal models in vivo for the presence of PET and optical signals. In this study, we describe the physical principles behind the operation of the OPET imaging system and discuss the design concept for one of the detector modules. Additionally, we demonstrate the operation of an initial prototype detector module for simultaneous detection and imaging of annihilation radiation and single optical photons emanating from separate sources. These results indicate that the construction of an imaging system based on this detector technology is feasible.Index Terms-Bioluminescence, microPET, positron emission tomography (PET), small animal imaging.
G8 is a bench top integrated PET/CT scanner dedicated to high sensitivity and high resolution imaging of mice. This work characterizes its National Electrical Manufacturers Association (NEMA) NU4-2008 performance where applicable and also provides an assessment of the basic imaging performance of the CT subsystem. The PET subsystem in G8 consists of four flat-panel type detectors arranged in a box like geometry. Each panel consists of two modules of a 26 × 26 pixelated bismuth germanate (BGO) scintillator array with individual crystals measuring 1.75 × 1.75 × 7.2 mm. The crystal arrays are coupled to multichannel photomultiplier tubes via a tapered, pixelated glass lightguide. A cone-beam CT consisting of a micro focus X-ray source and a Complementary Metal Oxide Semiconductor (CMOS) detector provides anatomical information. Sensitivity, spatial resolution, energy resolution, scatter fraction, count-rate performance and the capability of phantom and mouse imaging were evaluated for the PET subsystem. Noise, dose level, contrast and resolution were evaluated for the CT subsystem. With an energy window of 350-650 keV, the peak sensitivity was measured to be 9.0% near the center of the field of view (CFOV). The crystal energy resolution ranged from 15.0% to 69.6% full width at half maximum (FWHM), with a mean of 19.3 ± 3.7%. The average detector intrinsic spatial resolution was 1.30 mm and 1.38 mm FWHM in the transverse and axial directions. The maximum likelihood expectation maximization (ML-EM) reconstructed image of a point source in air, averaged 0.81 ± 0.11 mm FWHM. The peak noise equivalent count rate (NECR) for the mouse-sized phantom was 44 kcps for a total activity of 2.9 MBq (78 µCi) and the scatter fraction was 11%. For the CT subsystem, the value of the modulation transfer function (MTF) at 10% was 2.05 cycles/mm. The overall performance demonstrates that the G8 can produce high quality images for molecular imaging based biomedical research.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.