To improve pathogenetic studies in cancer development and reliable preclinical testing of anti-cancer treatments, three-dimensional (3D) cultures, including spheroids, have been widely recognized as more physiologically relevant in vitro models of in vivo tumor behavior. Currently, the generation of uniformly sized spheroids is still challenging: different 3D cell culture methods produce heterogeneous populations in dimensions and morphology, that may strongly influence readouts reliability correlated to tumor growth rate or antitumor natural killer (NK) cell-mediated cytotoxicity. In this context, an increasing consensus claims the integration of microfluidic technologies within 3D cell culture, as the physical characterization of tumor spheroids is unavoidably demanded to standardize protocols and assays for in vitro testing. In this paper, we employed a flow-based method specifically conceived to measure weight, size and focused onto mass density values of tumor spheroids. These measurements are combined with confocal and digital imaging of such samples. We tested the spheroids of four colorectal cancer (CRC) cell lines that exhibit statistically relevant differences in their physical characteristics, even though starting from the same cell seeding density. These variations are seemingly cell line-dependent and associated with the number of growing cells and the degree of spheroid compaction as well, supported by different adenosine-triphosphate contents. We also showed that this technology can estimate the NK cell killing efficacy by measuring the weight loss and diameter shrinkage of tumor spheroids, alongside with the commonly used cell viability in vitro test. As the activity of NK cells relies on their infiltration rate, the in vitro sensitivity of CRC spheroids proved to be exposure time- and cell line-dependent with direct correlation to the cell viability reduction. All these functional aspects can be measured by the system and are documented by digital image analysis. In conclusion, this flow-based method potentially paves the way towards standardization of 3D cell cultures and its early adoption in cancer research to test antitumor immune response and set up new immunotherapy strategies.
The controlled deposition of metal complexes from solution on inorganic surfaces offers access to functional materials that otherwise would be elusive. For such surface-confined interfaces to form, specific assembly sequences are often used. We show here that varying the assembly sequence of two well-defined and iso-structural osmium and ruthenium polypyridyl complexes results in interfaces with strikingly different spectroelectrochemical properties. Successive deposition of redox-active layers of osmium and ruthenium polypyridyl complexes, leads to self-propagating molecular assemblies (SPMAs) with distinct internal interfaces and individually addressable components. In contrast, the clear separation of these interfaces upon sequential deposition of these two complexes, results in charge trapping or electrochemical communication between the metal centers, as a function of layer thickness and applied assembly sequence. The SPMAs were characterized using a variety of techniques, including: UV–vis spectroscopy, spectroscopic ellipsometry, electrochemistry, synchrotron X-ray reflectivity, angle-resolved X-ray photoelectron spectroscopy, and spectroelectrochemistry. The combined data demonstrate that the sequence-dependent assembly is a decisive factor that influences and provides the material properties that are difficult to obtain otherwise.
The translation of continuous-flow microreactor technology to the industrial environment has been limited by cost and complexity of the fabrication procedures and the requirement for specialised infrastructure. In the present study, we have developed a significantly more cost-effective and easy-to-perform fabrication method for the generation of optically transparent, continuous-flow reactors. The method combines 3D printing of master moulds with sealing of the PDMS channels' replica using a pressure-sensitive adhesive tape. Morphological characterisation of the 3D printed moulds was performed and reactors were fabricated with an approximately square-shaped cross-section of 1 mm. Notably, they were tested for operation over a wide range of volumetric flow rates, up to 20 ml/min. Moreover, the fabrication time (i.e., from design to the finished product) was <1 day, at an average material cost of ∼£5. The flow reactors have been applied to the production of both inorganic nanoparticles (silver nanospheres) and organic vesicular systems (liposomes), and their performance compared with reactors produced using more laborious fabrication methods. Numerical simulations were performed to characterise the transport of fluids and chemical species within the devices. The developed fabrication method is suitable for scaled-up fabrication of continuous-flow reactors, with potential for application in biotechnology and nanomedicine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.