The American College of Sports Medicine (ACSM) gives the following definition of health-related physical fitness: Physical fitness is defined as a set of attributes that people have or achieve that relates to the ability to perform physical activity. It is also characterized by (1) an ability to perform daily activities with vigor, and (2) a demonstration of traits and capacities that are associated with a low risk of premature development of hypokinetic diseases (e.g., those associated with physical inactivity). Information from an individual's health and medical records can be combined with information from physical fitness assessment to meet the specific health goals and rehabilitative needs of that individual. Attaining adequate informed consent from participants prior to exercise testing is mandatory because of ethical and legal considerations.A physical fitness assessment includes measures of body composition, cardiorespiratory endurance, muscular fitness, and musculoskeletal flexibility. The three common techniques for assessing body composition are hydrostatic weighing, and skinfold measurements, and anthropometric measurements. Cardiorespiratory endurance is a crucial component of physical fitness assessment because of its strong correlation with health and health risks. Maximal oxygen uptake (VO2max) is the traditionally accepted criterion for measuring cardiorespiratory endurance. Although maximal-effort tests must be used to measure VO2max, submaximal exercise can be used to estimate this value. Muscular fitness has historically been used to describe an individual's integrated status of muscular strength and muscular endurance. An individual's muscular strength is specific to a particular muscle or muscle group and refers to the maximal force (N or kg) that the muscle or muscle group can generate. Dynamic strength can be assessed by measuring the movement of an individual's body against an external load. Isokinetic testing may be performed by assessing the muscle tension generated throughout a range of motion at a constant angular velocity. The ability of a muscle group to perform repeated contractions over a specific period of time that is sufficient to cause fatigue is termed muscular endurance. Musculoskeletal flexibility evaluations focus on the joints and associated structures, ligaments, and muscles that cross the joints. The sit-and-reach test and the behind-the-back reach test satisfy many of the criteria for physical assessment of musculoskeletal flexibility. A physical fitness assessment must be integrated into all activities of daily living, as well as the physician's examination, to assess and promote health.
The purpose of this report is to describe a crisis in healthcare, disabling back injuries in US healthcare workers. In addition, outlined is the proven solution of safe, mechanized, patient lifting, which has been shown to prevent these injuries. A "Safe Patient Handling--No Manual Lift" policy must be immediately instituted throughout this country. Such a policy is essential to halt hazardous manual patient lifting, which promotes needless disability and loss of healthcare workers, pain and risk of severe injury to patients, and tremendous waste of financial resources to employers and workers' compensation insurance carriers. Healthcare workers consistently rank among top occupations with disabling back injuries, primarily from manually lifting patients. Back injury may be the single largest contributor to the nursing shortage. Reported injuries to certified nursing assistants are three to four times that of registered nurses. A national healthcare policy for "Safe Patient Handling--No Manual Lift" is urgently needed to address this crisis. Body mechanics training is ineffective in prevention of back injury with patient lifting. Mandated use of mechanical patient lift equipment has proven to prevent most back injury to nursing personnel and reduce pain and injury to patients associated with manual lifting. With the national epidemic of morbid obesity in our country, innovative devices are available for use in emergency medical systems and hospitals for patient lifting and transfer without injury to hospital personnel. The US healthcare industry has not voluntarily taken measures necessary to reduce patient handling injury by use of mechanical lift devices. US healthcare workers who suffer disabling work-related back injuries are limited to the fixed, and often inadequate, relief which they may obtain from workers' compensation. Under workers' compensation law, healthcare workers injured lifting patients may not sue their employer for not providing mechanical lift equipment. Discarding healthcare workers disabled by preventable back injuries is an abuse which legislators must remedy. In addition, Medicare reimbursement policies must also be updated to allow the disabled community to purchase electrically operated overhead ceiling lifts. The US lags far behind countries with legislated manual handling regulations and "No Lifting" nursing policies. England and Australia have had "No Lifting" nursing policies in place since 1996 and 1998, respectively. The National Occupational Research Agenda (NORA) recognized a model in 2003 for reduction of back injuries to nursing staff in US healthcare facilities. Also in 2003, the American Nurses Association called for elimination of manual patient handling because it is unsafe and causes musculoskeletal injuries to nurses. The first state legislation for safe patient handling passed both houses in California but was vetoed by the Governor in September 2004. California and other states are preparing to (re)introduce legislation in January 2005. A national, industry-specific po...
It is the purpose of this collective review to provide a detailed outline of a revolutionary medical waste disposal system that should be used in all medical centers in the world to prevent pollution of our planet from medical waste. The Sanitec medical waste disposal system consists of the following seven components: (1) an all-weather steel enclosure of the waste management system, allowing it to be used inside or outside of the hospital center; (2) an automatic mechanical lift-and-load system that protects the workers from devastating back injuries; (3) a sophisticated shredding system designed for medical waste; (4) a series of air filters including the High Efficiency Particulate Air (HEPA) filter; (5) microwave disinfection of the medical waste material; (6) a waste compactor or dumpster; and (7) an onboard microprocessor. It must be emphasized that this waste management system can be used either inside or outside the hospital. From start to finish, the Sanitec Microwave Disinfection system is designed to provide process and engineering controls that assure complete disinfection and destruction, while minimizing the operator's exposure to risk. There are numerous technologic benefits to the Sanitec systems, including environmental, operational, physical, and disinfection efficiency as well as waste residue disinfection. Wastes treated through the Sanitec system are thoroughly disinfected, unrecognizable, and reduced in volume by approximately 80% (saving valuable landfill space and reducing hauling requirements and costs). They are acceptable in any municipal solid waste program. Sanitec's Zero Pollution Advantage is augmented by a complete range of services, including installation, startup, testing, training, maintenance, and repair, over the life of this system. The Sanitec waste management system has essentially been designed to provide the best overall solution to the customer, when that customer actually looks at the total cost of dealing with the medical waste issue. The Sanitec system is the right choice for healthcare and medical waste professionals around the world.
Syneture (division of U.S. Surgical, division of Tyco Healthcare, Norwalk, Connecticut, USA) STEEL sutures are monofilament stainless steel sutures composed of 316L stainless steel conforming to ASTM Standard F138 grade 2 (" Stainless steel bar and wire for surgical implant"). STEEL sutures meet all requirements established by the United States Pharmacopeia (USP) for nonabsorbable surgical sutures. Steel sutures are for use in abdominal wound closure, intestinal anastomosis, hernia repair, sternal closure, and skin closure. They are attached to the following types of surgical needles: Roto-Grip Needles and SCC Needle. The sutures and needles are packaged in a Mylar/Tyvek outer envelope. The purposes of this clinical review are two fold. First, we will report the performance of the Syneture STEEL suture product in the largest studies of suture performance ever reported in the literature. In addition, we will provide comprehensive information from the surgical literature that highlights the unique benefits of stainless steel sutures for the following wound closure techniques: sternal fixation, abdominal wound repair, inguinal hernia repair, and skin wound closure. Consorta Inc. (Rolling Meadows, Illinois), a leading healthcare resource management group purchasing organization, and Syneture, jointly with a clinician task force, designed a reproducible surgical evaluation program for needles and sutures in a large cooperative of healthcare systems. Because of the subjective nature of the more commonly used suture selection techniques, a nonexperimental observational study approach was designed to replace perception of performance characteristics with actual clinical experience. In a report involving 19 Consorta shareholder hospitals, they discussed the preliminary part (Phase I) of a large nonexperimental observational study of the clinical performance of surgical needles and sutures. Performance characteristics of the sutures and needles produced by Syneture that were evaluated in 3407 surgical procedures included packaging/ease of opening, needle strength and sharpness, tissue drag, knot security, tensile strength, clinically acceptable determinations, and clinically unacceptable determinations. In this preliminary study, the surgeons concluded that the needles and sutures were clinically acceptable in 98.1% of the evaluations. Armed with this favorable experience, we wanted to expand this observational study to an entirely new group of shareholder hospitals that had a larger number of participating hospitals (Phase I, 19 hospitals; Phase II, 42 hospitals). This more than doubling of hospital observational base dramatically increased the number of patients and performance evaluations. In the Phase II expanded program involving 42 hospitals, the number of patients (8939) and the number of evaluations (25,545) were more than twofold the preliminary study. In the phase I multicentric evaluation of Syneture surgical sutures, the performance of 9266 sutures was evaluated. Of these performance evaluations, 130 evaluation...
In March and early April 2009, Mexico experienced outbreaks of influenza caused by the H1N1 virus, which has spread throughout the world. With the pandemic of H1N1 infections, we have discussed in this scientific article strategies that should limit the spread of the influenza A (H1N1) virus in our country. Specific vaccines against the influenza H1N1 virus are being manufactured, and a licensed vaccine is expected to be available in the United States by mid-October 2009. However, some health-care workers may be hesitant to take a vaccine because it contains a mercury preservative-thimerosal-which can be harmful to their health. When caring for patients with respiratory infections, the health-care worker should be wearing a facial respirator. In a report from the Centers for Disease Control and Prevention (CDC), it was indicated that each health-care professional should be required to do a respiratory fit testing to identify the ideal model. Because it has been well documented that a vitamin D deficiency can precipitate the influenza virus, we strongly recommend that all health-care workers and patients be tested and treated for vitamin D deficiency to prevent exacerbation of a respiratory infection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.