Detecting QRS complexes or R-peaks from the electrocardiogram (ECG) is the basis for heart rate determination and heart rate variability analysis. Over the years, multiple different methods have been proposed as solutions to this problem. Vast majority of the proposed methods are traditional rule based algorithms that are vulnerable to noise. We propose a new R-peak detection method that is based on the Long Short-Term Memory (LSTM) network. LSTM networks excel at temporal modelling tasks that include long-term dependencies, making it suitable for ECG analysis. Additionally, we propose data generator for creating noisy ECG data that is used to train the robust R-peak detector. Our initial testing shows that the proposed method outperforms traditional algorithms while the greatest competitive edge is achieved with the noisy ECG signals.
Background Accurate, objective pain assessment is required in the health care domain and clinical settings for appropriate pain management. Automated, objective pain detection from physiological data in patients provides valuable information to hospital staff and caregivers to better manage pain, particularly for patients who are unable to self-report. Galvanic skin response (GSR) is one of the physiologic signals that refers to the changes in sweat gland activity, which can identify features of emotional states and anxiety induced by varying pain levels. This study used different statistical features extracted from GSR data collected from postoperative patients to detect their pain intensity. To the best of our knowledge, this is the first work building pain models using postoperative adult patients instead of healthy subjects. Objective The goal of this study was to present an automatic pain assessment tool using GSR signals to predict different pain intensities in noncommunicative, postoperative patients. Methods The study was designed to collect biomedical data from postoperative patients reporting moderate to high pain levels. We recruited 25 participants aged 23-89 years. First, a transcutaneous electrical nerve stimulation (TENS) unit was employed to obtain patients' baseline data. In the second part, the Empatica E4 wristband was worn by patients while they were performing low-intensity activities. Patient self-report based on the numeric rating scale (NRS) was used to record pain intensities that were correlated with objectively measured data. The labels were down-sampled from 11 pain levels to 5 different pain intensities, including the baseline. We used 2 different machine learning algorithms to construct the models. The mean decrease impurity method was used to find the top important features for pain prediction and improve the accuracy. We compared our results with a previously published research study to estimate the true performance of our models. Results Four different binary classification models were constructed using each machine learning algorithm to classify the baseline and other pain intensities (Baseline [BL] vs Pain Level [PL] 1, BL vs PL2, BL vs PL3, and BL vs PL4). Our models achieved higher accuracy for the first 3 pain models than the BioVid paper approach despite the challenges in analyzing real patient data. For BL vs PL1, BL vs PL2, and BL vs PL4, the highest prediction accuracies were achieved when using a random forest classifier (86.0, 70.0, and 61.5, respectively). For BL vs PL3, we achieved an accuracy of 72.1 using a k-nearest-neighbor classifier. Conclusions We are the first to propose and validate a pain assessment tool to predict different pain levels in real postoperative adult patients using GSR signals. We also exploited feature selection algorithms to find the top important features related to different pain intensities. In...
Background There is a strong demand for an accurate and objective means of assessing acute pain among hospitalized patients to help clinicians provide pain medications at a proper dosage and in a timely manner. Heart rate variability (HRV) comprises changes in the time intervals between consecutive heartbeats, which can be measured through acquisition and interpretation of electrocardiography (ECG) captured from bedside monitors or wearable devices. As increased sympathetic activity affects the HRV, an index of autonomic regulation of heart rate, ultra–short-term HRV analysis can provide a reliable source of information for acute pain monitoring. In this study, widely used HRV time and frequency domain measurements are used in acute pain assessments among postoperative patients. The existing approaches have only focused on stimulated pain in healthy subjects, whereas, to the best of our knowledge, there is no work in the literature building models using real pain data and on postoperative patients. Objective The objective of our study was to develop and evaluate an automatic and adaptable pain assessment algorithm based on ECG features for assessing acute pain in postoperative patients likely experiencing mild to moderate pain. Methods The study used a prospective observational design. The sample consisted of 25 patient participants aged 18 to 65 years. In part 1 of the study, a transcutaneous electrical nerve stimulation unit was employed to obtain baseline discomfort thresholds for the patients. In part 2, a multichannel biosignal acquisition device was used as patients were engaging in non-noxious activities. At all times, pain intensity was measured using patient self-reports based on the Numerical Rating Scale. A weak supervision framework was inherited for rapid training data creation. The collected labels were then transformed from 11 intensity levels to 5 intensity levels. Prediction models were developed using 5 different machine learning methods. Mean prediction accuracy was calculated using leave-one-out cross-validation. We compared the performance of these models with the results from a previously published research study. Results Five different machine learning algorithms were applied to perform a binary classification of baseline (BL) versus 4 distinct pain levels (PL1 through PL4). The highest validation accuracy using 3 time domain HRV features from a BioVid research paper for baseline versus any other pain level was achieved by support vector machine (SVM) with 62.72% (BL vs PL4) to 84.14% (BL vs PL2). Similar results were achieved for the top 8 features based on the Gini index using the SVM method, with an accuracy ranging from 63.86% (BL vs PL4) to 84.79% (BL vs PL2). Conclusions We propose a novel pain assessment method for postoperative patients using ECG signal. Weak supervision applied for labeling and feature extraction improves the robustness of the approach. Our results show the viability of using a machine learning algorithm to accurately and objectively assess acute pain among hospitalized patients. International Registered Report Identifier (IRRID) RR2-10.2196/17783
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.