SummaryBackgroundSurgical site infection (SSI) is one of the most common infections associated with health care, but its importance as a global health priority is not fully understood. We quantified the burden of SSI after gastrointestinal surgery in countries in all parts of the world.MethodsThis international, prospective, multicentre cohort study included consecutive patients undergoing elective or emergency gastrointestinal resection within 2-week time periods at any health-care facility in any country. Countries with participating centres were stratified into high-income, middle-income, and low-income groups according to the UN's Human Development Index (HDI). Data variables from the GlobalSurg 1 study and other studies that have been found to affect the likelihood of SSI were entered into risk adjustment models. The primary outcome measure was the 30-day SSI incidence (defined by US Centers for Disease Control and Prevention criteria for superficial and deep incisional SSI). Relationships with explanatory variables were examined using Bayesian multilevel logistic regression models. This trial is registered with ClinicalTrials.gov, number NCT02662231.FindingsBetween Jan 4, 2016, and July 31, 2016, 13 265 records were submitted for analysis. 12 539 patients from 343 hospitals in 66 countries were included. 7339 (58·5%) patient were from high-HDI countries (193 hospitals in 30 countries), 3918 (31·2%) patients were from middle-HDI countries (82 hospitals in 18 countries), and 1282 (10·2%) patients were from low-HDI countries (68 hospitals in 18 countries). In total, 1538 (12·3%) patients had SSI within 30 days of surgery. The incidence of SSI varied between countries with high (691 [9·4%] of 7339 patients), middle (549 [14·0%] of 3918 patients), and low (298 [23·2%] of 1282) HDI (p<0·001). The highest SSI incidence in each HDI group was after dirty surgery (102 [17·8%] of 574 patients in high-HDI countries; 74 [31·4%] of 236 patients in middle-HDI countries; 72 [39·8%] of 181 patients in low-HDI countries). Following risk factor adjustment, patients in low-HDI countries were at greatest risk of SSI (adjusted odds ratio 1·60, 95% credible interval 1·05–2·37; p=0·030). 132 (21·6%) of 610 patients with an SSI and a microbiology culture result had an infection that was resistant to the prophylactic antibiotic used. Resistant infections were detected in 49 (16·6%) of 295 patients in high-HDI countries, in 37 (19·8%) of 187 patients in middle-HDI countries, and in 46 (35·9%) of 128 patients in low-HDI countries (p<0·001).InterpretationCountries with a low HDI carry a disproportionately greater burden of SSI than countries with a middle or high HDI and might have higher rates of antibiotic resistance. In view of WHO recommendations on SSI prevention that highlight the absence of high-quality interventional research, urgent, pragmatic, randomised trials based in LMICs are needed to assess measures aiming to reduce this preventable complication.FundingDFID-MRC-Wellcome Trust Joint Global Health Trial Development Grant,...
Objective:This study aimed to analyze the interaction of Angiotensin II type 1 receptor (AT1R) gene polymorphism and occupational noise on the occurrence of essential hypertension (EH) in steel and iron enterprise men workers.Methods:A case control study of 935 iron and steel enterprise men workers was conducted, which included 312 cases of hypertension and 623 cases without hypertension. The noise at the workplace was assessed. Polymorphism of AT1R of the workers was examined using polymerase chain reaction - restriction fragment length polymorphism.Results:Polymorphism of AT1R (AC+CC vs. AA, odds ratio [OR] = 1.760, 95% confidence interval [CI]: 1.061∼2.920) and noise (greater than or equal to 85 dB(A),OR = 1.641, 95%CI: 1.225∼2.198) were independent determinants of EH using multivariate Logistic regression. Compared with AA carriers without noise, AC+CC interacted with noise (OR = 2.519, 95%CI: 1.254∼5.062) based on the multiplied model.Conclusions:AC+CC genotype of AT1R and noise were the risky factors of EH. These factors also interacted with each other.
Subhepatically located caecum and appendix is a very rare entity. It occurs due to the anomaly in fetal gut rotation that results in an incomplete rotation and fixation of the intestine. Appendicitis, which is a common surgical emergency, in combination with the abnormal subhepatic location, presents a great challenge in its diagnosis and management. Here, we describe a 42-year-old male with chronic dyspepsia who presented with sepsis and severe pain at his right hypochondriac and epigastric region. The final diagnosis was acute appendicitis of the subhepatic appendix. Our discussion focuses on the diagnostic approach and clinical and surgical management. We hope that our report will increase the awareness among the clinicians and hasten the management of such rare condition to avoid complications.
Ventriculostomy or external ventricular drain (EVD) placement by free-hand technique has a high malplacement rate. It is a blind procedure that often requires multiple attempts and revisions. To date, no neurological complication due to EVD malplacement has been reported in the literature. In this report, we present the first case of coma induced by a malplaced EVD and the patient regained consciousness after the drain was adjusted. Our discussion focused on various techniques that can improve the accuracy of EVD insertion. EVD insertion under image guidance provides better accuracy with limited disadvantages. We hypothesized that the patient's coma was due to the mass effect and irritation of the malplaced EVD exerted onto the ventral periaqueductal grey matter and the ascending neurons from upper brainstem. KeywOrds: Coma, Complications, External ventricular drain, Ventriculostomy, Hydrocephalus ÖZVentrikülostomi veya serbest eksternal ventriküler dren (EVD) yerleştirmenin yüksek bir yanlış yerleştirme oranı mevcuttur. Bu kör işlem çok sayıda girişim ve revizyon gerektirir. Günümüze kadar EVD yanlış yerleştirilmesi nedeniyle literatürde bir nörolojik komplikasyon bildirilmemiştir. Bu raporda, yanlış yerleştirilen EVD nedeniyle oluşan ilk koma vakasını sunuyoruz. Hastanın bilinci dren ayarlanırken tekrar yerine gelmiştir. Tartışmamız EVD insersiyonunun doğruluğunu arttırabilecek çeşitli tekniklere odaklanmaktadır. Görüntüleme kılavuzluğu altında EVD insersiyonu daha yüksek doğruluğa sahiptir ve dezavantajları sınırlıdır. Hastanın komasının yanlış yerleştirilen EVD'nin ventral periakuaduktal gri madde ve üst beyin kökünün çıkan nöronları üzerinde oluşturduğu kitle etkisi ve irritasyon sonucu oluştuğunu düşünmekteyiz.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.