Heart rate (HR) as an important physiological indicator could properly describe global subject’s physical status. Photoplethysmographic (PPG) sensors are catching on in field of wearable sensors, combining the advantages in costs, weight and size. Nevertheless, accuracy in HR readings is unreliable specifically during physical activity. Among several identified sources that affect PPG recording, contact pressure (CP) between the PPG sensor and skin greatly influences the signals. Methods: In this study, the accuracy of HR measurements of a PPG sensor at different CP was investigated when compared with a commercial ECG-based chest strap used as a test control, with the aim of determining the optimal CP to produce a reliable signal during physical activity. Seventeen subjects were enrolled for the study to perform a physical activity at three different rates repeated at three different contact pressures of the PPG-based wristband. Results: The results show that the CP of 54 mmHg provides the most accurate outcome with a Pearson correlation coefficient ranging from 0.81 to 0.95 and a mean average percentage error ranging from 3.8% to 2.4%, based on the physical activity rate. Conclusion: Authors found that changes in the CP have greater effects on PPG-HR signal quality than those deriving from the intensity of the physical activity and specifically, the individual best CP for each subject provided reliable HR measurements even for a high intensity of physical exercise with a Bland–Altman plot within ±11 bpm. Although future studies on a larger cohort of subjects are still needed, this study could contribute a profitable indication to enhance accuracy of PPG-based wearable devices.
Bicuspid aortic valve (BAV)-associated ascending aneurysmal aortopathy (namely "bicuspid aortopathy") is a heterogeneous disease making surgeon predictions particularly challenging. Computational flow analysis can be used to evaluate the BAV-related hemodynamic disturbances, which likely lead to aneurysm enlargement and progression. However, the anatomic reconstruction process is time consuming so that predicting hemodynamic and structural evolution by computational modeling is unfeasible in routine clinical practice. The aim of the study was to design and develop a parametric program for three-dimensional (3D) representations of aneurysmal aorta and different BAV phenotypes starting from several measures derived by computed-tomography angiography (CTA). Assuming that wall shear stress (WSS) has an important implication on bicuspid aortopathy, computational flow analyses were then performed to estimate how different would such an important parameter be, if a parametric aortic geometry was used as compared to standard geometric reconstructions obtained by CTA scans. Morphologic parameters here documented can be used to rapidly model the aorta and any phenotypes of BAV. t-test and Bland-Altman plot demonstrated that WSS obtained by flow analysis of parametric aortic geometries was in good agreement with that obtained from the flow analysis of CTA-related geometries. The proposed program offers a rapid and automated tool for 3D anatomic representations of bicuspid aortopathy with promising application in routine clinical practice by reducing the amount of time for anatomic reconstructions.
Endografts placed in the aorta for thoracic endovascular aortic repair (TEVAR) may determine malappositioning to the lesser curvature of the aortic wall, thus resulting in a devastating complication known as endograft collapse. This premature device failure commonly occurs in young individuals after TEVAR for traumatic aortic injuries as a result of applications outside the physical conditions for which the endograft was designed. In this study, an experimentally-calibrated fluid-structure interaction (FSI) model was developed to assess the hemodynamic and stress/strain distributions acting on the excessive protrusion extension (PE) of endografts deployed in four young patients underwent TEVAR. Endograft infolding was experimentally measured for different hemodynamic scenarios by perfusion testing and then used to numerically calibrate the mechanical behavior of endograft PE. Results evinced that the extent of endograft can severely alter the hemodynamic and structural loads exerted on the endograft PE. Specifically, PE determined a physiological aortic coarctation into the aortic arch characterized by a helical flow in the distal descending aorta. High device displacement and transmural pressure across the stent-graft wall were found for a PE longer than 21 mm. Finally, marked intramural stress and principal strain distributions on the protruded segment of the endograft wall may suggest failure due to material fatigue. These critical parameters may contribute to the endograft collapse observed clinically and can be used to design new devices more suitable for young individuals to be treated with an endoprosthesis for TEVAR of blunt traumatic aortic injuries.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.