An alcohol-associated change in the serum transferrin glycoform pattern, carbohydrate-deficient transferrin (CDT), is used as a biomarker of chronic moderate to heavy alcohol consumption. A current limitation in CDT analysis is the lack of standardization, which hampers clinical and analytical comparison between studies. This situation prompted initiation of a Working Group (WG) on CDT Standardization under the auspices of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). The standardization work aims to define and validate the analyte, select a reference method, work out procedures for the production of reference materials, and make suggestions for the clinical usage of CDT. The first recommendation of the WG is that disialotransferrin should be the primary target molecule for CDT measurement and the single analyte on which CDT standardization is based. It is further recommended that HPLC should be the analytical principle considered as the basis of an interim reference method until a suitable mass spectrometric reference method is established. In clinical use, CDT should be expressed in a relative amount (% CDT), to compensate for variations in the total transferrin concentration.
Carbohydrate-deficient transferrin (CDT) is a descriptive term used for a temporary change in the transferrin glycosylation profile caused by alcohol, and used as a biomarker of chronic high alcohol consumption. The use of an array of methods for measurement of CDT in various absolute or relative amounts, and sometimes covering different transferrin glycoforms, has complicated the comparability of results and caused confusion among medical staff. This situation prompted initiation of an IFCC Working Group on CDT standardization. This second publication of the WG-CDT covers the establishment of a network of reference laboratories running a high-performance liquid chromatography (HPLC) candidate reference measurement procedure, and evaluation of candidate secondary reference materials. The network laboratories demonstrated good and reproducible performance and thus can be used to assign target values for calibrators and controls. A candidate secondary reference material based on native human serum lyophilized with a cryo-/lyoprotectant to prevent protein denaturation was found to be commutable and stable during storage. A proposed strategy for calibration of different CDT methods is also presented. In an external quality assurance study involving 66 laboratories and covering the current routine CDT assays (HPLC, capillary electrophoresis and immunoassay), recalculation of observed results based on the nominal values for the candidate calibrator reduced the overall coefficient of variation from 18.9% to 5.5%. The logistics for distribution of reference materials and review of results were found to be functional, indicating that a full reference system for CDT may soon be available.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.