Nine patients (10 infusions) with a confirmed diagnosis of type 3 VWD were infused with von Willebrand factor (human), a preparation of von Willebrand factor (VWF) with a very low factor VIII content. Each patient was infused with one dose of approximately 50 or 100 iu ristocetin cofactor activity (VWF:RiCoF) per kg body weight. Bleeding times were performed during the 24 h period after infusion. Plasma samples were obtained over the 96 h period after infusion and were analysed for factor VIII coagulant activity (FVIIIC), VWF:RiCoF, von Willebrand factor antigen (VWF:Ag), and multimers. The FVIIIC data were analysed by non-linear least-squares analysis assuming constant FVIIIC 'synthesis' and exponential decay. The VWF data were fitted for exponential decay. The average decay rates for FVIIIC, VWF:RiCoF and VWF:Ag were 0.041, 0.061 and 0.056 respectively. The average calculated 'synthesis' rate for FVIIIC was 6.4 u/dl/h. The synthesis of FVIIIC was slightly faster and the decay slightly slower following the infusion of 100 iu VWF:RiCoF/kg than of 50 iu VWF:RiCoF/kg. Correction of the bleeding time was strongly dose dependent. At 4 h post infusion the median bleeding time was 9 min following a dose of 50 iu VWF:RiCoF/kg versus 3 min with a dose of 100 iu VWF:RiCoF/kg. There was no decrease in the bleeding time until the level of VWF:Ag or VWF:RiCoF reached > 100 u/dl.
An antibody to a high frequency antigen, made in a WES+ Black antenatal patient (Wash.), failed to react with the red cells of a presumed WES+ homozygote and is, therefore, probably antithetical to anti-WES. Like anti-WES, it reacted with papain, ficin, trypsin or neuraminidase treated cells but not with alpha-chymotrypsin or pronase treated cells and was specifically inhibited by concentrated serum. It also reacted more strongly in titration with WES- cells than with WES+ cells. The antibody is Cromer-related as it failed to react with Inab phenotype (IFC-) cells and reacted only weakly with Dr(a-) cells. Wash. cells and those of the other possible WES+ homozygote are Cr(a+) Tc(a+b-c-) Dr(a+) IFC+ but reacted only very weakly with anti-Esa.
A population of 73 donor samples was assembled on the basis of reactive results in routine screening with three different licensed human T-lymphotrophic virus type III (HTLV-III) antibody enzyme-linked immunosorbent assay (ELISA) procedures. The samples were retested by a number of licensed and developmental tests and by Western blot analysis. Our data indicate that nonspecific results are generated by ELISA tests and that many of these reactions appear to be directed against the cell substrate used to grow the virus. These findings suggest that combinations of currently licensed ELISA tests, based upon HTLV-III grown in H-9 cells, cannot be used to confirm the specificity of reactive samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.