[Purpose] To compare measurements of knee extensor and flexor muscle strength performed
using a hand-held dynamometer and an isokinetic dynamometer in apparently healthy
subjects. [Subjects and Methods] Thirty adult volunteers underwent knee muscle strength
evaluation using an isokinetic or a hand-held dynamometer. [Results] Strong positive
correlations were found between the 2 methods, with correlation coefficients r ranging
from 0.72 (95% confidence interval [CI], 0.48−0.86) to 0.87 (95% CI, 0.75−0.94), depending
on the muscle group and the isokinetic evaluation mode. The reproducibility of the
hand-held dynamometer findings was good, judged by a coefficient of variation of 3.2–4.2%.
However, the correlation between the 2 methods for the assessment of flexor/extensor
ratios ranged from −0.04 to 0.46. [Conclusion] Knee extensor and flexor muscle strength
recorded with a hand-held dynamometer is reproducible and significantly correlated with
the isokinetic values, indicating that this method may in some cases be a useful
replacement for isokinetic strength measurement. However, for strength ratio assessment,
and when judged against the isokinetic standard, a hand-held dynamometer is not a valid
option.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.