Background and Objectives The purpose of this study is to evaluate and establish the accuracy of noninvasive methods, including third-generation dual-source dual-energy computed tomography (DECT) and proton density fat (PDF) fraction on magnetic resonance imaging (MRI) using three-dimensional multiecho multipoint chemical shift-encoded spoiled gradient echo (q-Dixon) sequence in the quantification of hepatic steatosis; with H1-MR spectroscopy (MRS) as the reference standard. Materials and Methods A total of 47 patients were included in this prospective study. We studied the accuracy of fatty liver detection using third-generation DECT using mixed set images (MSIs), virtual monochromatic images (VMIs), and MRI q-Dixon. The results were compared with H1-MRS. Data were analyzed using linear regression for each technique compared with MRS. Results Our study's correlation and linear regression analysis showed a good correlation between PDF values obtained by H1-MRS and MR q-Dixon methods (r = 0.821, r 2 = 0.674, p < 0.001). On MSI, H1-MRS showed a low correlation with average liver attenuation (r 2 = 0.379, p < 0.001) and a moderate correlation with liver attenuation index (r 2 = 0.508, p < 0.001) noted. There was a moderate correlation between H1-MRS and average liver attenuation and liver attenuation index on VMI at 80 to 120 keV with r 2 = 0.434, p < 0.001, and r 2 = 0.485, p < 0.001, respectively. Conclusion MRI q-Dixon is the method of choice for evaluating fat quantification in the absence of H1 MRS. Among DECT images, VMI is valuable in the evaluation of hepatic fat as compared with the mixed set of images.
Purpose The purpose of this study is to evaluate the detection rate of pulmonary nodules in ultrashort echo time (UTE) lung magnetic resonance imaging (MRI) and to compare it with computed tomography (CT) in oncology patients. Materials and Methods All individuals undergoing radiotherapy/chemotherapy/regular follow-up or visiting the oncology department and referred to radiology department for nodule detection, during the period of 1 year, were subjected to UTE lung MRI using the sequence Flash 3d_spiralvibe coronal 1.25 mm iso and high-resolution CT lungs and the images were analyzed. Results Among the total number of nodules detected in both lungs of all patients, nodules detected by CT were 241, and nodules detected by MRI were 212. The nodule detection rate by MRI was 87.96%. The detection rate of nodules for size equal to or more than 5 mm was nearly 100%. For nodules less than 5 mm, and equal to or more than 4 mm, MRI showed a comparable detection rate of 75%, while for nodules less than 4 mm, the detection rate was only 25%. Conclusion Our study results indicate that lung MRI had a near-complete detection rate for nodules equal to or more than 5 mm in size. Hence, in oncology patients who are undergoing regular follow-up of the lung nodules, lung MRI using UTE can replace low-dose CT, which in turn reduces the radiation dose to the patient.
Background The purpose of this study was to compare the Image Quality, Contrast Medium Volume, and Radiation dose in renal angiography performed using Turbo Flash mode and dual-energy (DE) mode in the third-generation dual-source dual-energy CT. This prospective observational study was performed on renal donors who underwent CTA imaging as a pre-transplant workup. The study population was divided into two groups. Group A underwent DECT renal angiography. Group B underwent Turbo Flash Mode CT renal angiography. For group A, a contrast volume of 1 ml/kg and for group B at 0.5 ml/kg was administered. Image Quality was evaluated objectively by calculating CNR and SNR and subjectively by a 5-point scale. Radiation Dose analysis was done by noting CTDIvol and DLP on the scanner system and calculating effective radiation dose (ED). Results The subjective image quality scores for the Turbo Flash group were comparable with the DE group in qualitative image analysis. Additionally, in the Turbo Flash group, there was a reduction in contrast media and effective radiation dose by 47.5% and 32.7%, respectively. Nevertheless, mean attenuation of the abdominal arteries, CNR, SNR, and Noise (S.D) showed statistical significance between the two groups (p value < 0.01). Conclusions To our knowledge, no previous study compared Turboflash mode with DE protocol in CT renal angiography in a donor group of patients. Turbo Flash CT is an excellent modality that is faster and has an added advantage of decreased radiation dose and contrast media volume reduction, which can be recommended for screening of voluntary kidney donors but needs further clinical studies, validation, and standardization with tailored protocols.
Purpose:The aim of the study was to compare the image noise, radiation dose, and image quality of ultra-low-dose computed tomography (CT) and standard CT in the imaging of pulmonary pathologies. Material and methods:This observational study was performed between July 2020 and August 2021. All enrolled patients underwent both ultra-low-dose and standard CTs. The image noise, image quality for normal pulmonary structures, presence or absence of various pulmonary lesions, and radiation dose were recorded for each of the scans. The findings of standard-dose CT were regarded as the gold standard and compared with that of ultra-low-dose CT.Results: A total of 124 patients were included in the study. The image noise was higher in the ultra-low-dose CT compared to standard-dose CT. The overall image quality was determined to be diagnostic in 100% of standard CT images and in 96.77% of ultra-low-dose CT images with proportional worsening of the image quality as the body mass index (BMI) range was increased. Ultra-low-dose CT offered higher (> 90%) sensitivity for lesions like consolidation (97%), pleural effusion (95%), fibrosis (92%), and solid pulmonary nodules (91%). The effective radiation dose (mSv) was many times lower in ultra-low-dose CT when compared to standard-dose CT (mean ± SD: 0.50 ± 0.005 vs. 3.99 ± 1.57). Conclusions:The radiation dose of ultra-low-dose chest CT was almost equal to that of a chest X-ray. It could be used for the screening and/or follow-up of patients with solid pulmonary nodules (> 3 mm) and consolidation.
Catastrophic antiphospholipid syndrome (CAPS) is the rare but most severe form of antiphospholipid syndrome with multiple organ ischemia developing over a short period of time. CAPS should be considered when imaging suggests an acute and concurrent multiorgan ischemia, associated with positive antiphospholipid antibodies. As CAPS can have fulminant irreversible complications, its early recognition is important to initiate the treatment promptly. We present three patients of CAPS who were managed at our institution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.