Cystic renal lesions are commonly seen on a daily basis in abdominal imaging. Even though most cystic renal lesions are benign simple cysts, complex and multifocal cystic renal diseases are also common with a vast number of differentials. One of the rare mimickers of this condition is renal lymphangiectasia, and the disease can be diagnosed if radiologists are aware of the imaging findings, and this can help the physician to offer the appropriate treatment. We report a case series of five cases in our hospital and also review the literature on renal lymphangiectasia, including its pathophysiology, clinical presentation, imaging appearances, complications, treatment, and differentials.
Clock distribution networks are extremely critical from a performance and power standpoint. They account for about 20-30% of the total power dissipated in current generation microprocessors. Many three-dimensional (3D) schemes propose to reduce interconnect length to improve performance and decrease power consumption. In this paper we propose a clock distribution network for a 3D multilayer core microprocessor. The 3D microprocessor floor plan has a single core folded onto multiple layers. A separate layer for the clock distribution network is proposed in the 3D microprocessor. This arrangement of a 3D chip stack reduces (a) power lost in long interconnects at block level and (b) in the clock distribution. Simulation results indicate a 15-20% power saving for this clock distribution scheme as compared to a 2D structure. A methodology for turning off the global clock grid along with the logic for an entire layer in a 3D stack is also proposed. Simulation results indicate an additional 8-10% savings in power with minimal impact on the critical parameters of the clock grid.
Purpose: Renal fibrosis is the most common cause of allograft failure in kidney transplantations. Evaluation of renal abnormalities has progressed considerably over the past years. Currently, the diagnosis of intrarenal fibrosis and quantification of its development with non-invasive assessment tools is possible. This may help in early detection of renal allograft dysfunction. This study sought to assess the efficacy of 2D real-time shear-wave elastography (SWE) in the quantitative measurement of renal allograft dysfunction.Methods: A total of 172 patients were included in our study. SWE was performed in all these patients just before renal allograft biopsy. The cortical elasticity was assessed and described in terms of Young's modulus (kPa). Banff histopathological grading obtained from transplant kidney tissue biopsy was taken as the reference standard. The potential correlation between SWE scores and Banff classification was performed. Results:There was a significant correlation between the Banff grade and mean SWE score, with a correlation coefficient of 0.665 (p < 0.001). The individual correlation coefficients of interstitial fibrosis and tubular atrophy with mean SWE score stood at 0.667 and 0.649 respectively (p < 0.001). The correlation of resistive indices was insignificant when compared to mean polar SWE score in respective poles and the Banff grading of fibrosis. Conclusions:Renal stiffness quantified by 2D SWE showed significant correlation with histopathological renal fibrosis. Thus, the study suggests that shear-wave elastography could be used as a surrogate marker for early detection of renal fibrosis.
The aim of our study was to compare single-energy (SECT) and dual-energy (DECT) abdominal computed tomography (CT) examinations in matched patient cohorts regarding the differences in effective radiation dose (ERD) and image quality performed in a third-generation dual-source computed tomography (DSCT) scanner. Material and methods:Our study included 100 patients, who were divided randomly into 2 groups. The patients included in Group A were scanned by SECT, and Group B members were scanned by DECT. Volume CT dose index (CTDI vol ), dose length product (DLP), and ERD for venous phase acquisition were recorded in each patient and were normalised for 40 cm. Analyses were performed by using statistical software (SPSS version 20.0 for windows), and Bonferroni correction for multiple comparisons was applied for p-values and confidence intervals.Results: Average ERD based on DLP values normalised for 40 cm acquisition were obtained for both Group A and Group B. The mean ERD for Group A was 11.89 mSv, and for group B it was 6.87 mSv. There was a significant difference in these values between Group A and Group B as shown by a p-value of < 0.001. On subjective and objective analysis, there was no statistically significant difference in image quality between the 2 groups. Conclusions:The protocols in third-generation DSCT using dual-energy mode resulted in significant reductions in the effective radiation dose (by approximately 58%) compared to SECT in routine abdominal examination in matched cohorts. Therefore, the quantitative imaging potential of DECT can be utilised in needed patients with decreased radiation dose in third-generation DSCT.
Objectives The purpose of our study was to evaluate the virtual monochromatic imaging in detecting hypervascular focal liver lesions in the late arterial phase with third-generation dual-source dual-energy computed tomography and to assess its image quality. Materials and Methods In our study, 80 patients were included. Contrast-enhanced images in the late arterial phase (in the dual-energy mode) were acquired and were post-processed in Syngo, via workstation, using Monoenergetic + software. Five sets of images, one polychromatic energy image (corresponding to 120 kVp single-energy image) and four virtual monoenergetic image (VMI) sets at 40, 50, 60, and 70 keV levels, were generated. All these images were analyzed both objectively and subjectively. The attenuation values were measured, and the contrast-to-noise ratio (CNR) of liver and tumor were measured and compared objectively in each dataset. Image noise, image contrast, and diagnostic confidence for liver lesion detection were analyzed subjectively using a five-point scale system. Statistical analysis was performed using Kolmogorov–Smirnov, analysis of variance, and Kruskal–Wallis tests. Results Among the VMI, maximum image noise was observed in the 40 keV image, with a gradual reduction in the image noise being noted with an increase in the VMI energy. The CNR of the hepatic parenchyma and the tumor gradually increased with a reduction in VMI energy from 70 to 40 keV. On subjective analysis, image contrast and image noise were observed to be more in low VMI datasets. In lesion detection, diagnostic confidence with an excellent confidence level was observed with a decrease in VMI energy. Conclusion VMI datasets of 40 to 70 keV from third-generation dual-source DECT provide superior diagnostic accuracy for detecting hypervascular liver lesions. Considering the image noise and lesion detection rate among the VMI datasets, 60 keV VMI is the most helpful dataset for increased liver lesion detection with good image quality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.