Steroid-eluting epicardial leads have the same longevity as the conventional endocardial leads. Pacing and sensing thresholds were similar and did not change during follow-up. Therefore steroid-eluting epicardial pacing leads are a good alternative for endocardial leads in small children and in children with congenital heart disease.
New British guidelines on the treatment of asthma (9) advocate starting with a higher dose of inhaled corticosteroids in newly detected asthma patients. We investigated whether initiating inhaled steroid treatment with a higher dose is clinically more effective than a lower dose in steroid naive patients with asthma. The study had a 13-wk randomized, double-blind, parallel design: 1-mo treatment with 400 microg budesonide twice a day, or 100 microg budesonide twice a day by dry powder inhaler, and follow-up treatment period of 2 mo with 200 microg budesonide once daily for all patients. Forty patients started with 400 microg budesonide twice daily, 44 with 100 microg budesonide twice daily. Mean age was 32 yr, baseline FEV1 value 84% predicted, reversibility 9% from baseline, and mean bronchodilator use 1.6 inhalations/d in the run-in period. After 4 wk of treatment with 400 microg and 100 microg budesonide twice daily mean morning peak expiratory flow (PEF) increased 27 L/min (SD 50), and 38 L/ min (SD 53), respectively (p = 0.30); mean symptom score improved from 1.1 to 0.6 and from 1.1 to 0.5. These effects were maintained in the 2 mo follow-up. This study suggests that starting inhaled corticosteroids at a higher dose is not superior to a lower dose in the treatment of newly detected asthma.
Single unit recordings were made from the nerve branch innervating the crista in the horizontal semicircular canal of a pigeon. The vestibular organ was either stimulated with sound through the ear canal or with a vibrator in contact with the membraneous ampulla roof. Units responding to sound or vibration showed tuning with a best frequency of approximately 0.7 kHz. The average low-frequency slope of the tuning curves is--16 dB/oct; the average high-frequency slope 20 dB/oct. The threshold amplitude for vibrator stimulation is 30 nm. This value comes close to the calculated threshold value for cupula deflection in the human semicircular canal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.