Background: Milan System for Reporting Salivary Gland Cytology (MSRSGC) was introduced to standardise the terminology and reporting of salivary gland cytology.The purpose of our study was to compare the conventional system and the proposed Milan System to look for concordance rates in cytohistopathologic correlation and any value addition to the conventional system.Methods: This was a retrospective cross sectional observational study. The fine needle aspiration cytology (FNAC) were reported in the conventional manner and were correlated with the surgical specimen. The cyto-histopathological correlation was studied to look for concordance rates. FNAC were retrospectively reviewed and were categorised according to the Milan system. These reports were correlated with surgical specimen category wise and concordance rates, risk of neoplasm (RON), risk of malignancy (ROM) were calculated.Results: Salivary gland FNAC done during the study period was 323 in number and histopathological correlation was available for 153 cases. The concordance rate of type specific diagnosis was 80.3% as per conventional system. With the application of Milan system, the concordance rates rose to 88.07% with an improvement of 6.67%(excluding non-diagnostic). RON and ROM for non-diagnostic (I)-50%, 50%; non-neoplastic (II)-22%,0%; atypia of unknown significance (III)-66%, 11%; benign neoplasm (IVA)-98%, 3%; salivary gland neoplasm of uncertain malignant potential (IVB)-93%,14%; suspicious for malignancy (V)-100%, 60% and malignant (VI) was 100%, 94%.Conclusion: The broad categorisation provided by the Milan system represents the gross rate of malignancy and helps in deciding the management plan and eventual surgical plan. Thus, it adds value to conventional reporting of salivary gland cytology.K E Y W O R D S FNAC, Milan system, salivary gland cytology
Background and study aim Different types of endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) techniques are used in clinical practice; the best method in terms of outcome has not been determined. The aim of the study was to compare the diagnostic adequacy of aspirated material, and the cytopathological and EUS morphological features between capillary action, suction, and no-suction FNA methods. Patients and methods This was a prospective, single-blinded, randomized study conducted at a tertiary care hospital. Patients were randomized to the three groups: capillary action, suction, and no suction. A total of 300 patients were included, with 100 patients in each arm. Results A total of 300 patients (195 males) underwent EUS-FNA of 235 lymph nodes and 65 pancreatic masses (distribution not statistically different between the groups). The mean age was 52 ± 14 years. A 22 gauge needle was used in the majority (93 %) of procedures. There was no statistical difference between the three groups regarding lymph node size at the largest axis and ratio, type of needle, echo features, echogenicity, calcification, necrosis, shape, borders (lymph nodes), number of passes, and cellularity. Diagnostic adequacy of the specimen was 91 %, 91 %, and 94 % in the capillary, suction, and no suction groups, respectively ( P = 0.67). Significantly more slides and blood clots were generated by the suction method compared with the other methods. Conclusion The capillary action, suction, and no suction methods of EUS-FNA are similar in terms of diagnostic adequacy of the specimen. The suction method has the disadvantages of causing more bleeding and generating more slides.
Background/AimsEndoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) cytology of adrenal masses helps in etiological diagnosis. The aim of this study was to evaluate the diagnostic yield of EUS-FNA of adrenal masses in cases where other imaging methods failed and/or were not feasible.MethodsTwenty-one consecutive patients with adrenal masses, in whom adrenal FNA was performed because conventional imaging modalities failed and/or were not feasible, were prospectively evaluated over a period of 3 years.ResultsOf the 21 patients (mean age, 56±12.2 years; male:female ratio, 2:1), 12 had pyrexia of unknown origin and the other nine underwent evaluation for metastasis. The median lesion size was 2.4×1.6 cm. Ten patients were diagnosed with tuberculosis (shown by the presence of caseating granulomas [n=10] and acid-fast bacilli [n=4]). Two patients had EUS-FNA results suggestive of histoplasmosis. The other patients had metastatic lung carcinoma (n=6), hepatocellular carcinoma (n=1), and adrenal lipoma (n=1) and adrenal myelolipoma (n=1). EUS results were not suggestive of any particular etiology. No procedure-related adverse events occurred.ConclusionsEUS-FNA is a safe and effective method for evaluating adrenal masses, and it yields diagnosis in cases where tissue diagnosis is impossible or has failed using conventional imaging modalities.
Extramedullary plasmacytoma may occur either as an initial presentation or as a secondary involvement by multiple myeloma. Fine needle aspiration is a reliable technique for its rapid diagnosis.
Background and aims: Etiologic diagnosis of pyrexia of unknown origin is important in patients with cirrhosis for optimal management and to prevent flare up of infectious disease after liver transplantation. However, there is very limited literature available on this subject. The present study aimed to examine the safety and impact of endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) in patients with cirrhosis. Methods: The study was conducted between January 2014 and January 2016 at a tertiary care center. A total of 50 (47 lymph nodes, 3 adrenal) EUS guided FNAs were performed in 46 patients. Data are presented as median (25 – 75 IQR). Results: The study included 46 patients (40 males) whose mean age was 47.9 ± 11.1 (SD) years; mean Child-Turcotte-Pugh (CTP) score and mean MELD (Model for End-Stage Liver Disease) score were 10 (8 – 11) and 18 (12 – 20), respectively. The Child Pugh class was A in 4, B in 14, and C in 28 (including three patients with adrenal FNAs). Indications for FNA were pyrexia of unknown origin and lymphadenopathy on CT imaging. The cytopathological diagnoses were metastatic disease in 1 (adrenal), granulomatous change in 10 (6 positive with acid fast bacilli stain), histoplasmosis in three (two adrenals, one lymph node), 32 lymph nodes were reactive and four lymph node FNAs showed inadequate cellularity. The pathologic nodes had significantly lower long-to-short axis ratio [1.25 (1.09 – 1.28) versus 1.46 (1.22 – 1.87), P = 0.020]; a higher proportion of hypoechoic echotexture (5 versus 3, P = 0.017), and sharply defined borders (4 versus 2, P = 0.029). Complications included mild hepatic encephalopathy related to sedation in two patients with Child’s C status. Conclusion: EUS guided FNA is safe in patients with cirrhosis and modified the management in 14/46 (30.4 %) patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.