SummaryBackgroundMagnetic resonance enterography (MRE) and ultrasound are used to image Crohn's disease, but their comparative accuracy for assessing disease extent and activity is not known with certainty. Therefore, we did a multicentre trial to address this issue.MethodsWe recruited patients from eight UK hospitals. Eligible patients were 16 years or older, with newly diagnosed Crohn's disease or with established disease and suspected relapse. Consecutive patients had MRE and ultrasound in addition to standard investigations. Discrepancy between MRE and ultrasound for the presence of small bowel disease triggered an additional investigation, if not already available. The primary outcome was difference in per-patient sensitivity for small bowel disease extent (correct identification and segmental localisation) against a construct reference standard (panel diagnosis). This trial is registered with the International Standard Randomised Controlled Trial, number ISRCTN03982913, and has been completed.Findings284 patients completed the trial (133 in the newly diagnosed group, 151 in the relapse group). Based on the reference standard, 233 (82%) patients had small bowel Crohn's disease. The sensitivity of MRE for small bowel disease extent (80% [95% CI 72–86]) and presence (97% [91–99]) were significantly greater than that of ultrasound (70% [62–78] for disease extent, 92% [84–96] for disease presence); a 10% (95% CI 1–18; p=0·027) difference for extent, and 5% (1–9; p=0·025) difference for presence. The specificity of MRE for small bowel disease extent (95% [85–98]) was significantly greater than that of ultrasound (81% [64–91]); a difference of 14% (1–27; p=0·039). The specificity for small bowel disease presence was 96% (95% CI 86–99) with MRE and 84% (65–94) with ultrasound (difference 12% [0–25]; p=0·054). There were no serious adverse events.InterpretationBoth MRE and ultrasound have high sensitivity for detecting small bowel disease presence and both are valid first-line investigations, and viable alternatives to ileocolonoscopy. However, in a national health service setting, MRE is generally the preferred radiological investigation when available because its sensitivity and specificity exceed ultrasound significantly.FundingNational Institute of Health and Research Health Technology Assessment.
The aim of this study was to determine the extent to which gastric layering and retention of a meal could be used to reduce appetite using the same caloric load. Liquid (control) and semi-solid (active) meals were produced with the same protein, fat, carbohydrate, and mass. These were fed to 10 volunteers on separate days in a crossover study, and subjective appetite ratings, gastric contents, and plasma cholecystokinin (CCK) were assessed over a period of 3 h. The active meal showed food boluses in the stomach persisting for ~45 min, slower emptying rates, and lower plasma CCK levels over the first hour. After the first hour, both gastric emptying rates and plasma CCK levels were similar for both systems and slightly increased compared with the unfed situation. Despite the lower plasma CCK levels for the active meal over the first hour, this meal reduced appetite more than the control meal over the 3 h of the study. For a moderately increased plasma CCK level in the fed state, appetite was correlated with the volume of gastric contents rather than gastric emptying rates or plasma CCK. This suggests that enhanced gastric retention was the key factor in decreasing appetite and was probably mediated by a combination of intestinal nutrient sensing and increased viscosity in the stomach.
Summary Background Whole-body magnetic resonance imaging (WB-MRI) could be an alternative to multi-modality staging of non-small-cell lung cancer (NSCLC), but its diagnostic accuracy, effect on staging times, number of tests needed, cost, and effect on treatment decisions are unknown. We aimed to prospectively compare the diagnostic accuracy and efficiency of WB-MRI-based staging pathways with standard pathways in NSCLC. Methods The Streamline L trial was a prospective, multicentre trial done in 16 hospitals in England. Eligible patients were 18 years or older, with newly diagnosed NSCLC that was potentially radically treatable on diagnostic chest CT (defined as stage IIIb or less). Exclusion criteria were severe systemic disease, pregnancy, contraindications to MRI, or histologies other than NSCLC. Patients underwent WB-MRI, the result of which was withheld until standard staging investigations were complete and the first treatment decision made. The multidisciplinary team recorded its treatment decision based on standard investigations, then on the WB-MRI staging pathway (WB-MRI plus additional tests generated), and finally on all tests. The primary outcome was difference in per-patient sensitivity for metastases between standard and WB-MRI staging pathways against a consensus reference standard at 12 months, in the per-protocol population. Secondary outcomes were difference in per-patient specificity for metastatic disease detection between standard and WB-MRI staging pathways, differences in treatment decisions, staging efficiency (time taken, test number, and costs) and per-organ sensitivity and specificity for metastases and per-patient agreement for local T and N stage. This trial is registered with the International Standard Randomised Controlled Trial registry, number ISRCTN50436483, and is complete. Findings Between Feb 26, 2013, and Sept 5, 2016, 976 patients were screened for eligibility. 353 patients were recruited, 187 of whom completed the trial; 52 (28%) had metastasis at baseline. Pathway sensitivity was 50% (95% CI 37–63) for WB-MRI and 54% (41–67) for standard pathways, a difference of 4% (−7 to 15, p=0·73). No adverse events related to imaging were reported. Specificity did not differ between WB-MRI (93% [88–96]) and standard pathways (95% [91–98], p=0·45). Agreement with the multidisciplinary team's final treatment decision was 98% for WB-MRI and 99% for the standard pathway. Time to complete staging was shorter for WB-MRI (13 days [12–14]) than for the standard pathway (19 days [17–21]); a 6-day (4–8) difference. The number of tests required was similar WB-MRI (one [1–1]) and standard pathways (one [1–2]). Mean per-patient costs were £317 (273–361) for WBI-MRI and £620 (574–666) for standard pathways. Interpretation WB-MRI staging pathways have similar accuracy to standard pathways, and reduce the staging time and costs. Funding UK National Institute...
Background Whole-body MRI (WB-MRI) could be an alternative to multimodality staging of colorectal cancer, but its diagnostic accuracy, effect on staging times, number of tests needed, cost, and effect on treatment decisions are unknown. We aimed to prospectively compare the diagnostic accuracy and efficiency of WB-MRI-based staging pathways with standard pathways in colorectal cancer. Methods The Streamline C trial was a prospective, multicentre trial done in 16 hospitals in England. Eligible patients were 18 years or older, with newly diagnosed colorectal cancer. Exclusion criteria were severe systemic disease, pregnancy, contraindications to MRI, or polyp cancer. Patients underwent WB-MRI, the result of which was withheld until standard staging investigations were complete and the first treatment decision made. The multidisciplinary team recorded its treatment decision based on standard investigations, then on the WB-MRI staging pathway (WB-MRI plus additional tests generated), and finally on all tests. The primary outcome was difference in per-patient sensitivity for metastases between standard and WB-MRI staging pathways against a consensus reference standard at 12 months, in the per-protocol population. Secondary outcomes were difference in per-patient specificity for metastatic disease detection between standard and WB-MRI staging pathways, differences in treatment decisions, staging efficiency (time taken, test number, and costs), and per-organ sensitivity and specificity for metastases and per-patient agreement for local T and N stage. This trial is registered with the International Standard Randomised Controlled Trial registry, number ISRCTN43958015, and is complete.
A patient with right iliac fossa pain underwent CT angiography which demonstrated isolated caecal necrosis with associated superior mesenteric artery (SMA) stenosis. This was supported by colonoscopic findings and histopathological analysis. Isolated caecal necrosis is a rare presentation of ischaemic colitis.. Clinical and imaging findings of ischaemic colitis may mimic other pathologies. To improve diagnostic accuracy both referrers and radiologists should be aware of risk factors associated with ischaemic colitis. Isolated bowel wall thickening and pneumatosis of a colonic segment on CT are suggestive of focal bowel ischaemia, in the right clinical context.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.