The SF/TPU sheet had excellent mechanical properties and tissue biocompatibility. These favorable features and possible biodegradability of the SF portion warrant a long-term follow-up study.
The SHF may solve the drawbacks of the existing products. Further studies of the expandability of the SHF patch after degradation of PLLA are warranted.
The safety and efficacy of landiolol have not been fully elucidated in pediatric patients. This study aimed to clarify the safety and efficacy of landiolol in a pediatric cohort. We retrospectively assessed the clinical features of 21 pediatric patients who were administered landiolol at our hospital. We also investigated the rates of sinus rhythm conversion and heart rate response. The median patient age was 7 months (interquartile range 1–13 months). The etiology of tachyarrhythmia was junctional ectopic tachycardia in 10 patients (47.6%), atrial tachycardia in 10 patients (47.6%), and ventricular tachycardia in 1 patient (4.8%). Of the 21 children, 18 (85.7%) had congenital heart defects, including 14 (77.8%) in whom a landiolol infusion was performed perioperatively. The landiolol infusion was effective in 18 pediatric patients (85.7%), as measured by the conversion to sinus rhythm or a reduced heart rate. Atrial tachycardia in the perioperative period was terminated in all patients. Of 7 patients with tachyarrhythmias unrelated to the perioperative period, landiolol was effective in 5. No adverse effects were reported in any patient. Landiolol infusion is effective and safe in pediatric patients with tachyarrhythmia of various etiologies, especially those with atrial tachyarrhythmia during the perioperative period.
Objectives Air leakage after lung resection is a common morbidity that may lengthen hospital stay. Applying sealant to a lesion is an effective prophylaxis in clinical practice. The aim of this study was to examine the effect of a combination of a bioabsorbable polyglycolic acid (PGA) fabric and fibrin glue (FG) on air sealing by measuring the in vitro mechanical strength and degradation of the fabric, and in vivo histological changes after implantation. Methods A defect was created in the canine left upper lung lobe, and then filled with fibrinogen solution and covered with a PGA sheet spray-coated with fibrinogen and thrombin. After 1 and 4 weeks, air leakage from the lesion was examined in vivo under airway pressure. Tissue samples were harvested for histological assessment. Results The mechanical strength of the PGA fabric remained at 80–90% of the baseline level for 1 week in phosphate buffered saline (PBS), and then rapidly decreased to zero thereafter. Air leakage from the lung defect was prevented by the combination of PGA fabric and FG at 1 and 4 weeks. Histological examinations showed that PGA bundles persisted with a non-specific inflammatory response for 2 weeks and then gradually broke into sparse yarns surrounded by collagen fibers and capillaries by 8 weeks. The lung defect was filled with FG at 1 week and by granulation tissue thereafter. Conclusions These results provide evidence for the efficacy of a combination of PGA fabric and FG for prevention of air leakage in the critical period after lung surgery.
BackgroundThe rupture of the posterior ventricular septum after acute inferior myocardial infarction is more challenging to repair than ruptures in other sites since it is less accessible and anatomically restricted. We described a modification of Daggett’s original technique of multi-patch repair of ruptured posterior septum.Case presentationThe technique was employed in the operation of a 67-year-old male who presented with severe heart failure at the 10th day after he developed inferior myocardial infarction. His ventricular septum had ruptured at the level between the posteromedial papillary muscle and the mitral annulus.A large endoventricular patch covered separately over the locally patched septal defect and the ventriculotomy defect which was going to be roofed eventually with an external patch. Both defects were then individually closed in double layers, holding a single continuous patch in common. The common use of a single patch expedited multilayered closure of the left ventricular defects and could minimize geometric remodeling of the covered area. The patches on both the endocardial and the epicardial sides avoided potentially fatal bleeding from the ventriculotomy site. The transmural mattress sutures incorporating ventriculotomy patches required minimal bites toward the posteromedial papillary muscle and mitral annulus, thereby preserving the mitral valve function.ConclusionsThus, the technique enhances the advantage of the left ventriculotomy in the repair of posterior septal rupture and avoids ventriculotomy-related morbidity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.