Background: Thermal ablation is a definitive local treatment for selected colorectal liver metastases (CLM) that can be ablated with adequate margins. A critical limitation has been local tumor progression (LTP). Methods: This prospective, single-group, phase 2 study enrolled patients with CLM < 5 cm in maximum diameter, at a tertiary cancer center between November 2009 and February 2019. Biopsy of the ablation zone center and margin was performed immediately after ablation. Viable tumor in tissue biopsy and ablation margins < 5 mm were assessed as predictors of 12-month LTP. Results: We enrolled 107 patients with 182 CLMs. Mean tumor size was 2.0 (range, 0.6–4.6) cm. Microwave ablation was used in 51% and radiofrequency ablation in 49% of tumors. The 12- and 24-month cumulative incidence of LTP was 22% (95% confidence interval [CI]: 17, 29) and 29% (95% CI: 23, 36), respectively. LTP at 12 months was 7% (95% CI: 3, 14) for the biopsy tumor-negative ablation zone with margins ≥ 5 mm vs. 63% (95% CI: 35, 85) for the biopsy-positive ablation zone with margins < 5 mm (p < 0.001). Conclusions: Biopsy-proven complete tumor ablation with margins of at least 5 mm achieves optimal local tumor control for CLM, regardless of the ablation modality used.
Background: Real-time split-dose PET can identify the targeted colorectal liver metastasis (CLM) and eliminate the need for repeated contrast administration before and during thermal ablation (TA). This study aimed to assess the added value of pre-ablation real-time split-dose PET when combined with non-contract CT in the detection of CLM for ablation and the evaluation of the ablation zone and margins. Methods: A total of 190 CLMs/125 participants from two IRB-approved prospective clinical trials using PET/CT-guided TA were analyzed. Based on detection on pre-TA imaging, CLMs were categorized as detectable, non-detectable, and of poor conspicuity on CT alone, and detectable, non-detectable, and low FDG-avidity on PET/CT after the initial dose. Ablation margins around the targeted CLM were evaluated using a 3D volumetric approach. Results: We found that 129/190 (67.9%) CLMs were detectable on CT alone, and 61/190 CLMs (32.1%) were undetectable or of poor conspicuity, not allowing accurate depiction and targeting by CT alone. Thus, the theoretical 5- and 10-mm margins could not be defined in these tumors (32.1%) using CT alone. When TA intraprocedural PET/CT images are obtained and inspected (fused PET/CT), only 4 CLM (2.1%) remained undetectable or had a low FDG avidity. Conclusions: The addition of PET to non-contrast CT improved CLM detection for ablation targeting, margin assessments, and continuous depiction of the FDG avid CLMs during the ablation without the need for multiple intravenous contrast injections pre- and intra-procedurally.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.