Several methods of measuring the migration of the femoral component after total hip replacement have been described, but they use different reference lines, and have differing accuracies, some unproven. Statistical comparison of different studies is rarely possible.We report a study of the EBRA-FCA method (femoral component analysis using Einzel-Bild-Röntgen-Analyse) to determine its accuracy using three independent assessments, including a direct comparison with the results of roentgen stereophotogrammetric analysis (RSA).The accuracy of EBRA-FCA was better than ±1.5 mm (95% percentile) with a Cronbach's coefficient alpha for interobserver reliability of 0.84; a very good result.The method had a specificity of 100% and a sensitivity of 78% compared with RSA for the detection of migration of over 1 mm. This is accurate enough to assess the stability of a prosthesis within a relatively limited period. The best reference line for downward migration is between the greater trochanter and the shoulder of the stem, as confirmed by two experimental analyses and a computer-assisted design.
Several methods of measuring the migration of the femoral component after total hip replacement have been described, but they use different reference lines, and have differing accuracies, some unproven. Statistical comparison of different studies is rarely possible. We report a study of the EBRA-FCA method (femoral component analysis using Einzel-Bild-Röntgen-Analyse) to determine its accuracy using three independent assessments, including a direct comparison with the results of roentgen stereophotogrammetric analysis (RSA). The accuracy of EBRA-FCA was better than +/- 1.5 mm (95% percentile) with a Cronbach's coefficient alpha for interobserver reliability of 0.84; a very good result. The method had a specificity of 100% and a sensitivity of 78% compared with RSA for the detection of migration of over 1 mm. This is accurate enough to assess the stability of a prosthesis within a relatively limited period. The best reference line for downward migration is between the greater trochanter and the shoulder of the stem, as confirmed by two experimental analyses and a computer-assisted design.
Background and purposeLittle is known about the comparative performance of patient-reported outcome measures in revision hip arthroplasty. We compared the performance of the WOMAC, the SF-36, the EQ-5D, and a pain-related visual analog scale (VAS) in revision hip arthroplasty.Methods45 patients with aseptic prosthetic loosening following primary hip arthroplasty completed the WOMAC, the SF-36, the EQ-5D, and a VAS for pain—at baseline and 2 years after revision. Responsiveness of the measures was compared with the effect size (with ≥ 0.8 being considered large). Agreement between scales measuring the same type of outcome (pain or physical function) was assessed with the Bland-Altman method.ResultsThe mean preoperative scores for the pain and physical function scales of WOMAC and SF-36, EQ-5D index, and VAS for pain improved statistically significantly 2 years after revision. The effect size for the WOMAC pain was 1.7, that for SF-36 pain was 1.4, that for WOMAC physical function was 1.6, that for SF-36 physical function was 0.8, and that for EQ-5D index was 1.2. The VAS for pain had an effect size of 2.1, which was larger than that for SF-36 pain and for the EQ-5D index (p ≤ 0.03) but not for WOMAC pain (p = 0.2). The limits of agreement between WOMAC pain, SF-36 pain, and the VAS scale measuring pain—and between the WOMAC and SF-36 scales measuring physical function—were wide. Internal-consistency reliability was high for the WOMAC and SF-36 scales but low for the EQ-5D.InterpretationIn patients with first-time revision hip arthroplasty done for aseptic loosening, the WOMAC, SF-36, and EQ-5D showed high responsiveness in measuring patient-reported outcomes and the simple VAS for pain performed equally well.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.