In this study, we assessed the validity and reliability of 5 and 10 Hz global positioning systems (GPS) for measuring instantaneous velocity during acceleration, deceleration, and constant velocity while straight-line running. Three participants performed 80 running trials while wearing two GPS units each (5 Hz, V2.0 and 10 Hz, V4.0; MinimaxX, Catapult Innovations, Scoresby, VIC, Australia). The criterion measure used to assess GPS validity was instantaneous velocity recorded using a tripod-mounted laser. Validity was established using the standard error of the estimate (± 90% confidence limits). Reliability was determined using typical error (± 90% confidence limits, expressed as coefficient of variation) and Pearson's correlation. The 10 Hz GPS devices were two to three times more accurate than the 5 Hz devices when compared with a criterion value for instantaneous velocity during tasks completed at a range of velocities (coefficient of variation 3.1-11.3%). Similarly, the 10 Hz GPS units were up to six-fold more reliable for measuring instantaneous velocity than the 5 Hz units (coefficient of variation 1.9-6.0%). Newer GPS may provide an acceptable tool for the measurement of constant velocity, acceleration, and deceleration during straight-line running and have sufficient sensitivity for detecting changes in performance in team sport. However, researchers must account for the inherent match-to-match variation reported when using these devices.
Electromechanical delay (EMD) in isometric contractions of knee extensors evoked by voluntary, tendon reflex (TR) and electrical stimulation (ES) was investigated in 21 healthy young subjects. The subject performed voluntary knee extensions with maximum effort (maximal voluntary contraction, MVC), and at 30%, 60% and 80% MVC. Patellar tendon reflexes were evoked with the reflex hammer being dropped from 60 degrees, 75 degrees and 90 degrees positions. In the percutaneous ES evoked contractions, single switches were triggered with pulses of duration 1.0 ms and of intensities 90, 120 and 150 V. Electromyograms of the vastus lateralis and rectus femoris muscles were recorded using surface electrodes. The isometric knee extension force was recorded using a load cell force transducer connected to the subject's lower leg. The major finding of this study was that EMD of the involuntary contractions [e.g. mean 22.1 (SEM 1.32) ms in TR 90 degrees; mean 17.2 (SEM 0.62) ms in ES 150 V] was significantly shorter than that of the voluntary contractions [e.g. mean 38.7 (SEM 1.18) ms in MVC, P < 0.05]. The relationships between EMD, muscle contractile properties and muscle fibre conduction velocity were also investigated. Further study is needed to explain fully the EMD differences found between the voluntary and involuntary contractions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.